The various classes and types of connectors are intended for
application as follows:
a. MIL-DTL-28840/10 - are receptacles intended for wall or
bulkhead flange mounting and are for use with conduit, backshells
or cable clamps.
b. MIL-DTL-28840/11 - are receptacles intended for use at the
end of a cable where mounting provisions are not required.
c. MIL-DTL-28840/12 - are receptacles intended for mounting on
shielding boxes and equipment cases. They have no fittings and are
for use with open wiring. Individual wires should not exceed 12
inches in length. Box mount connectors should be used only in
controlled atmosphere applications where environmental sealing is
not required.
d. MIL-DTL-28840/14 - are receptacles intended for wall or
bulkhead jam nut mounting and for use with conduit or a cable
clamp.
e. MIL-DTL-28840/16 - are plugs intended for use at the end of a
cable to be mated with a receptacle.
f. MIL-DTL-28840/18 - are 90° plugs intended for use at the end
of a cable where space does not permit the use of a straight
plug.
g. Connectors are intended for use with jacketed cables where
the connectors will be subjected to high-impact shock conditions
beyond the capabilities of the other class connectors. These
connectors have crimp contacts which are removed from the front of
the connector and a wire sealing range capable of sealing on Naval
shipboard cable. These connectors also have a specified shell
conductivity.
h. These connectors are intended for use where the connector
will be subject to heavy condensation and rapid changes in
temperature or pressure, and where the connector is subject to high
vibratory conditions. A MIL-DTL-28840/12 type receptacle does not
provide moisture or vibration protection at its back end, and a
MIL-DTL-28840/10 type or MIL-DTL-28840/11 type receptacle should be
used if such protection is desired.
View Less