NPFC - MIL-C-24640
CABLES, LIGHT-WEIGHT, ELECTRIC, FOR SHIPBOARD USE, GENERAL SPECIFICATION FOR
| Organization: | NPFC |
| Publication Date: | 26 June 1995 |
| Status: | inactive |
| Page Count: | 83 |
scope:
This specification covers light weight electric cables for Navy shipboard applications.
Cables covered by this specification shall be classified as watertight, non-watertight and non-watertight with circuit integrity constructions, armored and unarmored, unarmored with overall shields and further classified for power, control, communications, instrumentation and electronic applications, as specified in 1.2.1 through 1.2.3 (see 6.2.1). A part number for cable and cord shall be as specified in 6.8 and the applicable specification sheet.
Cable types for non-watertight, nonflexing service as follows:
Power: Unarmored Unarmored with Armored overall shield Type DX ---- DXA Two conductors 600 volts (V) FX ---- FXA Four conductors 600 V TX ---- TXA Three conductors 600 V
Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, SEA 05Q42, Naval Sea Systems Command, 2531 National Center Bldg. 3, Washington, DC 20362-5160, by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter.
Electronic, communication and instrumentation: Unarmored Unarmored with Armored overall shield Type ---- MXO ---- Multi-conductor, AWG 20 600 V ---- MXSO ---- Multi-conductor, AWG 16 600 V TTX ---- TTXA Multi-pair, AWG 20 600 V TTXS TTXSO TTXSA Multi-pair, AWG 22 600 V ---- 1XMSO ---- Multi-conductor, AWG 22 600 v ---- 2XAO ---- Multi-pair, AWG 22 600 V ---- 2XO ---- Multi-pair, AWG 26 600 V 2XS 2XSO 2XSA Multi-pair, AWG 22 600 V ---- 2XSXO ---- Multi-pair, AWG 26 600 V 3XS ---- 3XSA Multi-triad, AWG 18 600 V
Cable types for watertight, non-flexing service are as follows:
Electronic, communication and instrumentation: Unarmored Unarmored with Armored overall shield Type ---- 1XSOW ---- Multi-conductor, AWG 22 600 V ---- 2XOW ---- Multi-pair, AWG 26 600 V 2XSAW 2XSAOW 2XSAWA Multi-pair, AWG 22 600 V 2XSW 2XSOW 2XSWA Multi-pair, AWG 18 600 V 3XSW 3XSOW 3XSWA Multi-triad, AWG 22 600 V
Cable types for watertight with circuit integrity, nonflexing service are as follows:
Power: Unarmored Unarmored with Armored overall shield Type DXW DXOW DXWA Two conductor 600 V FXW FXOW FXWA Four conductor 600 V TXW TXOW TXWA Three conductor 600 V 7XW ---- 7XWA Seven conductor 600 V Electronic, communication and instrumentation: Unarmored Unarmored with Armored overall shield Type TTXW TTXOW TTXWA Multi-pair, AWG 22 600 V Control: Unarmored Unarmored with Armored overall shield Type MXCW MXCOW MXCWA Multi-conductor, AWG 18 600 V
intended Use:
Cables specified herein are intended for use in various applications involving naval ships and shore stations.