ASTM International - ASTM ISO/ASTM51650-05

Standard Practice for Use of Cellulose Acetate Dosimetry Systems

inactive
Buy Now
Organization: ASTM International
Publication Date: 15 May 2005
Status: inactive
Page Count: 7
significance And Use:

4.1 The cellulose triacetate (CTA) dosimetry system provides a means for measuring absorbed dose in materials (2-15). The dosimeter is a film containing cellulose triacetate and plasticizer. The... View More

scope:

1.1 This practice covers procedures for using the cellulose triacetate (CTA) dosimetry system for measuring absorbed dose and dose profile in materials irradiated by electrons and photons in terms of absorbed dose to water. The CTA dosimeter is a routine dosimeter especially useful for measurement of dose distribution.

Note 1

Cellulose triacetate dosimeter refers to untinted film dosimeter.

1.2 This practice applies provided the following conditions are satisfied.

1.2.1 The absorbed-dose range is 10 kGy to 300 kGy for electrons and photons.

1.2.2 The absorbed-dose rate range is 3 Gy/s to 410 10 Gy/s ().

1.2.3 The radiation-energy range for electrons is 0.2 to 50 MeV.

1.2.4 The radiation-energy range for photons is 0.1 to 50 MeV.

1.2.5 The irradiation-temperature range of the dosimeter is -10 to 70C.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Document History

June 1, 2012
Standard Practice for Use of a Cellulose Triacetate Dosimetry System
1.1 This is a practice for using a cellulose triacetate (CTA) dosimetry system to measure absorbed dose in materials irradiated by photons or electrons in terms of absorbed dose to water. The CTA...
ASTM ISO/ASTM51650-05
May 15, 2005
Standard Practice for Use of Cellulose Acetate Dosimetry Systems
4.1 The cellulose triacetate (CTA) dosimetry system provides a means for measuring absorbed dose in materials (2-15). The dosimeter is a film containing cellulose triacetate and plasticizer. The...
January 22, 2002
Standard Practice for Use of Cellulose Acetate Dosimetry Systems
1.1 This practice covers the preparation, handling, testing and procedures for the use of cellulose acetate dosimetry systems, and the spectrometric, densitometric, or photometric readout equipment...