IEC TR 60919-1
Performance of high-voltage d.c. (HVDC) systems Part 1: Steady-state conditions
inactive
Buy Now
| Organization: | IEC |
| Publication Date: | 1 December 1988 |
| Status: | inactive |
| Page Count: | 132 |
| ICS Code (Other equipment related to power transmission and distribution networks): | 29.240.99 |
| ICS Code (Rectifiers. Converters. Stabilized power supply): | 29.200 |
Document History
April 1, 2020
Performance of high-voltage direct current (HVDC) systems with line‑commutated converters – Part 1: Steady-state conditions
This part of IEC 60919 provides general guidance on the steady-state performance requirements of high-voltage direct current (HVDC) systems. It concerns the steady-state performance of two-terminal...
May 1, 2017
Performance of high-voltage direct current (HVDC) systems with linecommutated converters - Part 1: Steady-state conditions
This part of the IEC 60919 provides general guidance on the steady-state performance requirements of high-voltage direct current (HVDC) systems. It concerns the steady-state performance of...
May 1, 2017
AMENDMENT 2 Performance of high-voltage direct current (HVDC) systems with line-commutated converters – Part 1: Steady-state conditions
A description is not available for this item.
April 1, 2013
Amendment 1 Performance of high-voltage direct current (HVDC) systems with line-commutated converters – Part 1: Steady-state conditions
A description is not available for this item.
April 1, 2013
Performance of high-voltage direct current (HVDC) systems with line-commutated converters – Part 1: Steady-state conditions
This part of the IEC 60919 provides general guidance on the steady-state performance requirements of high-voltage direct current (HVDC) systems. It concerns the steady-state performance of...
May 1, 2010
Performance of high-voltage direct current (HVDC) systems with line-commutated converters – Part 1: Steady-state conditions
This part of the IEC 60919 provides general guidance on the steady-state performance requirements of high-voltage direct current (HVDC) systems. It concerns the steady-state performance of...
March 1, 2005
Performance of high-voltage direct current (HVDC) systems with line-commutated converters Part 1: Steady-state conditions
This technical report provides general guidance on the steady-state performance requirements of HVDC systems. It concerns the steady-state performance of two-terminal HVDC systems utilizing 12-pulse...
IEC TR 60919-1
December 1, 1988
Performance of high-voltage d.c. (HVDC) systems Part 1: Steady-state conditions
A description is not available for this item.