UNLIMITED FREE
ACCESS
TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

DS/EN 61000-4-30

Electromagnetic compatibility (EMC) - Part 4-30: Testing and measurement techniques - Power quality measurement methods

inactive
Organization: DS
Publication Date: 22 May 2003
Status: inactive
Page Count: 51
ICS Code (Other aspects related to EMC): 33.100.99
scope:

This part of 61000-4 defines the methods for measurement and interpretation of results for power quality parameters in 50/60 Hz a.c. power supply systems. Measurement methods are described for each relevant type of parameter in terms that will make it possible to obtain reliable, repeatable and comparable results regardless of the compliant instrument being used, and regardless of its environmental conditions. This standard addresses measurement methods for in-situ measurements. measurement of parameters covered by this standard is limited to those phenomena that can be conducted in a power system. These include the voltage and/or curent parameters, as appropriate. The power quality parameters considered in this standard are power frequency, magnitude of the supply voltage, flicker, supply voltage dips and swells, voltage interruptions, transient voltages, supply voltage unbalance, voltage and current harmonics and interharmonics, mains signalling on the supply voltage and rapid voltage changes. Depending on the purpose of the measurement, all or a subset of the phenomena on this list may be measured. This standard is a performance specification, not a design specification. The uncertainty tests in the ranges of influence quantities in thos standard determine the performance requirements. This standard gives measurement methods but does not set thresholds. The effect of tranducers being inserted between the power system and the instrument are acknowledged but not addressed in detail in this standard. Precautions on installing monitors on live circuits are addressed.

Document History

April 19, 2021
Electromagnetic compatibility (EMC) – Part 4-30: Testing and measurement techniques – Power quality measurement methods
IEC 61000-4-30:201 5 defines the methods for measurement and interpretation of results for power quality parameters in a.c. power supply systems with a declared fundamental frequency of 50 Hz or 60...
January 24, 2017
Electromagnetic compatibility (EMC) – Part 4-30: Testing and measurement techniques – Power quality measurement methods
<span style='color:red'>NEW!</span> IEC 61000-4-30:2015 is available as <a href="http://webstore.iec.ch/webstore/webstore.nsf/Artnum_PK/9999977878?opendocument">IEC Standards+...
May 27, 2015
Electromagnetic compatibility (EMC) - Part 4-30: Testing and measurement techniques - Power quality measurement methods
<span style='color:red'>NEW!</span> IEC 61000-4-30:2015 is available as <a href="http://webstore.iec.ch/webstore/webstore.nsf/Artnum_PK/9999977878?opendocument">IEC Standards+...
February 11, 2009
Electromagnetic compatibility (EMC) – Part 4-30: Testing and measurement techniques – Power quality measurement methods
This part of IEC 61000-4 defines the methods for measurement and interpretation of results for power quality parameters in 50/60 Hz a.c. power supply systems. Measurement methods are described for...
January 19, 2007
Electromagnetic compatibility (EMC) - Part 4-30: Testing and measurement techniques - Power quality measurement methods
This part of 61000-4 defines the methods for measurement and interpretation of results for power quality parameters in 50/60 Hz a.c. power supply systems. Measurement methods are described for each...
DS/EN 61000-4-30
May 22, 2003
Electromagnetic compatibility (EMC) - Part 4-30: Testing and measurement techniques - Power quality measurement methods
This part of 61000-4 defines the methods for measurement and interpretation of results for power quality parameters in 50/60 Hz a.c. power supply systems. Measurement methods are described for each...
Electromagnetic compatibility (EMC) – Part 4-30: Testing and measurement techniques – Power quality measurement methods
<span style='color:red'>NEW!</span> IEC 61000-4-30:2015 is available as <a href="http://webstore.iec.ch/webstore/webstore.nsf/Artnum_PK/9999977878?opendocument">IEC Standards+...
Electromagnetic compatibility (EMC) - Part 4-30: Testing and measurement techniques - Power quality measurement methods
This part of IEC 61000-4 defines the methods for measurement and interpretation of results for power quality parameters in a.c. power supply systems with a declared fundamental frequency of 50 Hz or...
Electromagnetic compatibility (EMC) -- Part 4-30 : Testing and measurement techniques - Power quality measurement methods
This part of IEC 61000-4 defines the methods for measurement and interpretation of results for power quality parameters in 50/60 Hz a.c. power supply systems. Measurement methods are described for...
Electromagnetic Compatibility (EMC) -- Part 4-30: Testing and measurement techniques - Power quality measurement methods
This part of IEC 61000-4 defines the methods for measurement and interpretation of results for power quality parameters in a.c. power supply systems with a declared fundamental frequency of 50 Hz or...
Advertisement