ANS - 56.8

Containment System Leakage Testing Requirements

inactive
Organization: ANS
Publication Date: 1 January 1994
Status: inactive
Page Count: 41
scope:

This standard specifies acceptable primary containment leakage rate test requirements to assure valid testing. The scope includes

(1) Leakage test requirements

(2) Test instrumentation

(3) Test procedures

(4) Test methods

(5) Acceptance criteria

(6) Data analysis

(7) Inspection and reporting of test results.

Purpose. This standard provides a basis for determining leakage rates through the primary containment of light-water reactor nuclear power plants.

The examples given in various sections of this standard do not contain or modify any requirements. These examples are for illustration only and clarify the intent of the text. Furthermore, the examples are not meant to be all-inclusive. Examples of alternative methods or exceptions to general requirements do not constitute permission to categorically apply the exceptions. Each alternative or exception needs to be evaluated to determine its validity and effect.

1At the time this standard was approved, it contained certain requirements (i.e., testing frequency requirements) that were not fully consistent with existing regulations in the United States. The user of the standard should ensure that its application in a regulated facility is appropriate.

Document History

January 1, 2020
Containment System Leakage Testing Requirements
This standard1) specifies acceptable primary containment leakage rate test requirements. The scope includes (1) leakage test requirements; (2) test instrumentation; (3) test procedures; (4) test...
January 1, 2002
Containment System Leakage Testing Requirements
This standard specifies acceptable primary containment leakage rate test requirements to assure valid testing. The scope includes (1) leakage test requirements; (2) test instrumentation; (3) test...
January 1, 2002
Containment System Leakage Testing Requirements
This standard specifies acceptable primary containment leakage rate test requirements to assure valid testing. The scope includes 1) leakage test requirements; 2) test instrumentation; 3) test...
January 1, 2002
Containment System Leakage Testing Requirements
This standard specifies acceptable primary containment leakage rate test requirements to assure valid testing. The scope includes (1) leakage test requirements; (2) test instrumentation; (3) test...
January 1, 2002
Containment System Leakage Testing Requirements
This standard specifies acceptable primary containment leakage rate test requirements to assure valid testing. The scope includes 1) leakage test requirements; 2) test instrumentation; 3) test...
56.8
January 1, 1994
Containment System Leakage Testing Requirements
This standard specifies acceptable primary containment leakage rate test requirements to assure valid testing. The scope includes (1) Leakage test requirements (2) Test instrumentation (3) Test...
January 20, 1987
CONTAINMENT SYSTEM LEAKAGE TESTING REQUIREMENTS
A description is not available for this item.
January 1, 1981
CONTAINMENT SYSTEM LEAKAGE TESTING REQUIREMENTS
The provisions of this standard specify the minimum acceptable primary reactor containment system leakage rate test requirements to assure valid testing. The scope includes: (a) Test methods (b)...