UNLIMITED FREE
ACCESS
TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

DS/IEC 60287-2-1

Electric cables – Calculation of the current rating – Part 2-1: Thermal resistance – Calculation of the thermal resistance

active, Most Current
Buy Now
Organization: DS
Publication Date: 27 April 2015
Status: active
Page Count: 44
ICS Code (Cables): 29.060.20
scope:

IEC 60287-2-1:2015 is available as a href="http://webstore.iec.ch/webstore/webstore.nsf/Artnum_PK/99999201588?opendocument"IEC Standards+ 60287-2-1:2015 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60287-2-1:2015 is solely applicable to the conditions of steady-state operation of cables at all alternating voltages, and direct voltages up to 5 kV, buried directly in the ground, in ducts, in troughs or in steel pipes, both with and without partial drying-out of the soil, as well as cables in air. The term "steady state" is intended to mean a continuous constant current (100 % load factor) just sufficient to produce asymptotically the maximum conductor temperature, the surrounding ambient conditions being assumed constant. This part of IEC 60287 provides formulae for thermal resistance. This second edition of IEC 60287-2-1 cancels and replaces the first edition, published in 1994, Amendment 1:2001, Amendment 2:2006 and Corrigendum 1:2008. This edition includes the following significant technical changes with respect to the previous edition; a) inclusion of a reference to the use of finite element methods where analytical methods are not available for the calculation of external thermal resistance; b) explanation about SL and SA type cables; c) calculation method for T3 for unarmoured three-core cables with extruded insulation and individual copper tape screens on each core; d) change of condition for X in 5.4; e) inclusion of constants or installation conditions for water filled ducts in Table 4.

Document History

May 31, 2023
Electric cables – Calculation of the current rating – Part 2-1: Thermal resistance – Calculation of thermal resistance
IEC 60287-2-1:2023 is solely applicable to the conditions of steady-state operation of cables at all alternating voltages, and direct voltages up to 5 kV, buried directly in the ground, in ducts, in...
DS/IEC 60287-2-1
April 27, 2015
Electric cables – Calculation of the current rating – Part 2-1: Thermal resistance – Calculation of the thermal resistance
IEC 60287-2-1:2015 is available as a href="http://webstore.iec.ch/webstore/webstore.nsf/Artnum_PK/99999201588?opendocument"IEC Standards+ 60287-2-1:2015 which contains the International Standard and...
Electric cables – Calculation of the current rating – Part 2-1: Thermal resistance – Calculation of the thermal resistance
This part of IEC 60287 is solely applicable to the conditions of steady-state operation of cables at all alternating voltages, and direct voltages up to 5 kV, buried directly in the ground, in ducts,...
IEC 60287-2-1: Electric cables - Calculation of the current rating - Part 2-1: Thermal resistance - Calculation of thermal resistance
This part of IEC 60287 is solely applicable to the conditions of steady-state operation of cables at all alternating voltages, and direct voltages up to 5 kV, buried directly in the ground, in ducts,...
Advertisement