4.1 This practice is applicable to non-chromate coatings that are colorless, colored, electrochemically applied or non-electrochemicall
1.1 This test method covers the determination of the dynamic elastic properties of advanced ceramics. Specimens of these materials possess specific mechanical resonant frequencies that are determined by the elastic modulus, mass, and geometry of the test specimen. Therefore, the dynamic elastic...
4.1 The moisture retaining ability of a product as determined by this test method is used to assess the suitability of materials for contributing to an appropriate curing environment for concrete. The laboratory test method is used both in formulating and in specifying or qualifying curing products...
5.1 Rolling friction like sliding friction depends upon many factors. It is a system effect that involves the nature of the specimen and the rolling surface. The sliding friction force (F) is usually considered to be the sum of forces arising from deformations of surface features (Fs), from...
4.1 Water can cause the degradation of coatings, so knowledge of how a coating resists water is helpful for assessing how it will perform in actual service. Failure in tests at 100?% relative humidity may be caused by a number of factors including a deficiency in the coating itself, contamination...
1.1 This test method covers the determination of the elastic properties of ceramic whiteware materials. Specimens of these materials possess specific mechanical resonance frequencies which are defined by the elastic moduli, density, and geometry of the test specimen. Therefore the elastic...
4.1 This test method is used for measuring the relative abilities of metal preservatives to prevent the rusting of steel panels under conditions of high humidity. It should not be relied upon to predict the effectiveness of a metal preservative in which high humidity is not the principal factor in...
1.1 This test method evaluates the preheat energy consumption, idle energy consumption, and dynamic energy consumption of hot food holding cabinets. The food service operator can use this evaluation to select a hot food holding cabinet and understand its energy performance,...
This test method details the standard procedure for the determination of modulus of rupture of ceramic whiteware clays, both dry and after conditioning at specified relative humidity, or both. The apparatuses needed for this method are a conditioning cabinet, and a testing machine. Extruded,...
1.1 This test method evaluates the preheat energy consumption and idle energy consumption of compartmentalized heated bin cabinets. The food service operator can use this evaluation to select a compartmentalized heated bin cabinet and understand its energy performance and temperature...
This specification covers four types of pozzolanic hydraulic lime for structural purposes which include use in mortar, scratch, brown, and finish (stucco) coats of interior or exterior plaster. The four types of pozzolanic hydraulic lime are classified according to the minimum hydrated lime...
This specification provides design and construction criteria for double and single fire and foam station cabinets. These cabinets are classified as Type I (single cabinet) and Type II (double cabinets). Type I cabinets are further subdivided into two grades: Grade...
4.1 This practice is applicable to chromate coatings of the colorless (both one and two-dip), iridescent yellow or bronze, olive drab, black, colorless anodic, yellow or black anodic types, and of the dyed variety, when applied to surfaces of electrodeposited zinc, mechanically deposited zinc,...
This specification defines standard environment for normal conditioning and testing of paint, varnish, lacquer, and related coating materials. Conditioning and testing of such materials shall be carried out in an atmosphere having room temperature and relative humidity within the limits of the...
1.1 These requirements cover electric dry-bath heating equipment and other equipment rated 600 volts or less that is intended to produce a dry-heat environment to be installed in accordance with the National Electrical Code, ANSI/NFPA 70. The relative humidity in the heated environment is in the...
This practice covers the conditioning and testing of textiles in those instances where such conditioning is specified in a test method. Because prior exposure of textiles to high or low humidity may affect the equilibrium moisture pick-up, a procedure also is given for preconditioning the material...
1.1 This practice covers the general requirements for achieving and maintaining temperatures below 21°C for thermal conditioning and physical testing of rubber. 1.2 This practice describes the acceptable types and construction of low-temperature cabinets for conditioning and testing of...
1.1 The techniques described in this guide pertain to mixed flowing gas (MFG) tests containing species that are applied to evaluate devices containing electrical contacts such as slip rings, separable connectors, electromechanical relays or switch contacts. These techniques may be relevant to other...
This specification covers the design, performance, and certification requirements pertinent to the construction of commercial automatic ice making machines used in manufacturing and processing ice, including the attached equipment used in storing and dispensing the produced ice for human...
1.1 This standard applies to enclosures for electrical equipment intended to be installed and used in non-hazardous locations in accordance with the Canadian Electrical Code, Part I, CSA C22.1, the provisions of the National Electrical Code, NFPA 70, and the provisions of Mexico's Electrical...