loading
J1293_201604 - Undervehicle Coupon Corrosion Tests
April 5, 2016 - SAE International

This document is a road test procedure for comparing the corrosion resistance of both coated and uncoated sheet steels in an undervehicle deicing salt environment.

NACE RP0775 - Preparation, Installation, Analysis, and Interpretation of Corrosion Coupons in Oilfield Operations
June 25, 1999 - NACE

General This standard is presented for the use of corrosion coupons in oilfield drilling, production, and transportation operations. Oilfield operations include oil-, water-, and gashandling systems, and drilling fluids. (When used in this standard, system denotes a functional unit...

ASTM G4-95 - Standard Guide for Conducting Corrosion Coupon Tests in Field Applications
October 10, 2001 - ASTM International

1.1 This guide covers procedures for conducting corrosion tests in plant equipment or systems under operating conditions to evaluate the corrosion resistance of engineering materials. It does not cover electrochemical methods for determining corrosion rates. 1.1.1 While...

CTI STD-149 - Corrosion Testing Procedures Corrosion Coupon Testing and Test Devices
October 1, 2000 - CTI
A description is not available for this item.
GM CORROSION - GM CORROSION AVOIDANCE * MUST HAVE GM AUTHORIZATION - SEE FORM *
GMNA
A description is not available for this item.
ISO HDBK CORROSION - ISO STANDARDS HANDBOOK - CORROSION
ISO
A description is not available for this item.
NACE TM0193 - Laboratory Corrosion Testing of Metals in Static Chemical Cleaning Solutions at Temperatures Below 93 Degrees C (200 Degrees F)
June 16, 2000 - NACE

ABSTRACT Describes a simple method for measuring the relative corrosiveness of inhibited solutions used for chemical cleaning in a static system; the tests described are conducted with corrosion coupons in a clean solution. Addresses testing parameters not covered in ASTM D 3263,...

ASTM F1110-09(2020) - Standard Test Method for Sandwich Corrosion Test
November 1, 2020 - ASTM International

5.1 The data generated by this test method shall be used to determine whether aircraft structural aluminum alloys are liable to be corroded or damaged by application of the test material during routine maintenance operations. 5.2 Interpretation of the sandwich corrosion test results is based...

ASTM F1110-09 - Standard Test Method for Sandwich Corrosion Test
May 15, 2009 - ASTM International

The data generated by this test method shall be used to determine whether aircraft structural aluminum alloys are liable to be corroded or damaged by application of the test material during routine maintenance operations. Interpretation of the sandwich corrosion test results is based on a...

ASTM F1110-08 - Standard Test Method for Sandwich Corrosion Test
May 1, 2008 - ASTM International

The data generated by this test method shall be used to determine whether aircraft structural aluminum alloys are liable to be corroded or damaged by application of the test material during routine maintenance operations. Interpretation of the sandwich corrosion test results is based on a...

ASTM F1110-09(2014) - Standard Test Method for Sandwich Corrosion Test
December 1, 2014 - ASTM International

5.1 The data generated by this test method shall be used to determine whether aircraft structural aluminum alloys are liable to be corroded or damaged by application of the test material during routine maintenance operations. 5.2 Interpretation of the sandwich corrosion test results is based...

ASTM F1110-02 - Standard Test Method for Sandwich Corrosion Test
August 10, 2002 - ASTM International

The data generated by this test method shall be used to determine whether aircraft structural aluminum alloys are liable to be corroded or damaged by application of the test material during routine maintenance operations. Interpretation of the sandwich corrosion test results is based on a...

NACE 05107 - Report on Corrosion Probes in Soil or Concrete
August 1, 2007 - NACE

General Structure-to-soil potential measurements to determine the effectiveness of CP is sometimes prone to error due to unstable reference cell contact or high soil IR drops. In certain soil environments, effective CP is achieved even at potentials less negative than the applicable criteria (on or...

NACE SP0104 - The Use of Coupons for Cathodic Protection Monitoring Applications
August 14, 2020 - NACE

ABSTRACT Cathodic protection (CP) coupons have been used since the 1930s by pioneers of the corrosion control industry, both in North America and in Europe. They have been shown to be a practical tool for determining the level of polarization of a structure and to confirm the IR drop...

NACE RP0104 - The Use of Coupons for Cathodic Protection Monitoring Applications
December 3, 2004 - NACE

General A CP coupon may be used to determine the level of CP of a buried or submerged metallic structure. CP coupons are installed in the electrolyte near the structure and are then connected to it through a test station. This allows the CP coupon to be connected to the CP...

ASTM G189-07(2021)e1 - Standard Guide for Laboratory Simulation of Corrosion Under Insulation
January 1, 2021 - ASTM International

1.1 This guide covers the simulation of corrosion under insulation (CUI), including both general and localized attack, on insulated specimens cut from pipe sections exposed to a corrosive environment usually at elevated temperature. It describes a CUI exposure apparatus (hereinafter referred...

ASTM G189-07(2013) - Standard Guide for Laboratory Simulation of Corrosion Under Insulation
August 1, 2013 - ASTM International

1.1 This guide covers the simulation of corrosion under insulation (CUI), including both general and localized attack, on insulated specimens cut from pipe sections exposed to a corrosive environment usually at elevated temperature. It describes a CUI exposure apparatus (hereinafter referred...

DS/ISO 22426 - Assessment of the effectiveness of cathodic protection based on coupon measurements
February 18, 2020 - DS

This document specifies requirements for the design, installation, positioning, sizing, use and maintenance of coupons for the assessment of the effectiveness of cathodic protection (CP) of buried and immersed metallic structures, such as pipelines, in the case of normal operation as well as...

ISO 22426 - Assessment of the effectiveness of cathodic protection based on coupon measurements
February 1, 2020 - ISO

This document specifies requirements for the design, installation, positioning, sizing, use and maintenance of coupons for the assessment of the effectiveness of cathodic protection (CP) of buried and immersed metallic structures, such as pipelines, in the case of normal operation as well as...

Advertisement