1.1 This classification covers rigid Poly(Vinyl Chloride)(PVC), Chlorinated Poly(Vinyl Chloride)(CPVC), copolymers, blends and alloys, and composite materials derived from recyclate from extruded, molded or calendared forms or operations and composed of polyvinyl chloride, chlorinated polyvinyl...
1.1 This practice describes procedures for conducting comprehensive surveys of buildings and facilities for the purpose of locating, identifying, quantifying, and assessing asbestos-containing materials. 1.2 The results of a comprehensive building asbestos survey are intended to be used for ongoing...
5.1 The ability to accurately measure the airtightness of a portion of a building envelope is significant to diagnostic testing, compliance testing, ventilation and space conditioning load calculations, and energy modelling of discrete portions of a building. 5.2 Zonal testing is particularly...
4.1 Purpose-This guide provides a process for identifying, prioritizing, selecting, implementing, documenting, and reporting activities to reduce the environmental footprint of a cleanup as defined by the following core elements. 4.1.1 Minimize Total Energy Use and Maximize Use of Renewable...
1.1 This guide provides guidance for the handling, physical condition and compositional considerations for selecting scrap gypsum panel products and the recycled gypsum derived from that scrap for recycling into new gypsum panel products. 1.2 This guide applies to material derived from gypsum panel...
1.1 This practice describes a method for selecting samples of building components coated with paints suspected of containing lead. The samples are collected from the debris waste stream created during demolition, renovation, lead hazard control, abatement, or other projects. The samples are...
5.1 The Hi-Vol sampler is commonly used for the collection of the airborne particulate component of the atmosphere. Some physical and chemical parameters of the collected particulate matter are dependent upon the physical characteristics of the collection system and the choice of filter media. A...
1.1 The purpose of this guide is to facilitate development of a waste management plan for construction, deconstruction, or demolition projects (hereafter, construction waste management (CWM) plan). 1.2 This guide applies to CWM plans developed for construction, renovation, deconstruction,...
1.1 This guide provides a consistent basis for assessing methane in the vadose zone, evaluating hazard and risk, determining the appropriate response, and identifying the urgency of the response. 1.2 Purpose-This guide covers techniques for evaluating potential hazards associated with methane...
This SAE Recommended Practice applies only to excavators, as defined in ISO 6165, working above ground, near an excavated or free-standing bank or mine face which is higher than the top of the cab, or in demolition applications of freestanding buildings or objects higher than the top of the...
5.1 The extraction of minerals from the Earth's crust usually requires fracturing rock with tools made from metals, which have been clad, overlaid, or coated in some fashion with high hardness or wear-resistant materials, or both. Drilling, crushing, and moving rock involves high-stress abrasion on...
This standard applies to all construction and demolition workers with potential noise exposures (continuous, intermittent and impulse) of 85 dBA and above. Purpose This standard is intended to help employers prevent occupational hearing loss among construction and demolition workers.
This standard provides the required elements and activities on construction and demolition projects to protect the public. Purpose This standard is intended for use as a system to protect the public.
4.1 The purpose of this standard is to provide the user information and guidance for selecting and using instrumentation that will provide measurement results that can be compared to criteria for unrestricted use. 4.2 Use of this standard will provide greater assurance that the measurements...
Scope. This specification describes the requirements and verification methods for the following items: DUMMY BOOSTER, DEMOLITION CHARGE: NON-ELECTRIC, 30 FT INERT DETONATING CORD - M652
This Standard sets out minimum requirements for the design, construction and testing of electrical installations that supply electricity to appliances and equipment on construction and demolition sites, and for the in-service testing of portable, transportable and fixed electrical equipment...
4.1 NDA measurement practices aimed at achieving quality results are described in this guide. The application of the material provided in this guide should be determined on a case by case basis. Not all elements are required for all applications. 4.2 Nondestructive assay measurements are typically...
This document applies to all signal boxes, listed and non-listed redundant signal boxes in both conservation areas, and non-conservation areas. Asbestos may well be present in signal boxes and if that is the case Network Rail's standard on Asbestos Management NR/L2/CIV/168 should be followed. This...
Building. Part II of this code provides requirements for buildings and structures and includes provisions for structural strength, stability, sanitation, means of access and egress, light and ventilation, safety to life and protection of property from fire and, in general, to secure life and...
General. The procedures contained herein detail the methods for establishing item names and type designations as associated with specific categories and types of Army materiel. These procedures are referred to as the Army Nomenclature System and define the intent, limitations and process involved...
Narrow Your Results