1.1 This test method covers the determination of dielectric strength of solid electrical insulating materials under simulated-lightning impulse conditions. 1.2 Procedures are given for tests using standard 1.2 by 50?μs full-wave impulses. 1.3 This test method is intended for use in determining the...
This specification covers a precipitation hardening bolting material (UNS N07718) for high temperature service. The alloy shall be multiple melted using consumable electrode practice in the remelt cycle or shall be induction melted under vacuum. Requirements for solution treatment,...
4.1 Controlled relative humidity environments are important for conditioning materials for shelf-life studies or for investigating the change in physical or dielectric properties after exposure. 4.2 The use of aqueous-glycerin solutions reduces the possibility of contamination of the materials or...
1.1 This test method applies to the determination of hydrogen in nuclear-grade uranium oxide powders and pellets to determine compliance with specifications. Gadolinium oxide (Gd2O3) and gadolinium oxide-uranium oxide powders and pellets may also be analyzed using this test method. 1.2 This...
This specification covers the chemical, particle size, and cleanliness requirements for unalloyed titanium and titanium-6aluminum-4
1.1 These test methods cover procedures for the chemical and mass spectrometric analysis of nuclear-grade gadolinium oxide powders to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Carbon by Direct Combustion-Thermal Conductivity...
3.1 Cationic emulsified asphalts are identified by the migration of the particles to a negatively charged electrode (cathode) by means of a direct current. Aggregates and sands used in conjunction with emulsified asphalts are often predominantly either negatively or positively charged....
1.1 This terminology covers those terms recommended by the International Union of Pure and Applied Chemistry (IUPAC), and is intended to provide guidance in the use of ion-selective electrodes for analytical measurement of species in water, wastewater, and brines. 1.2 This international...
1.1 These reference radiographs illustrate various types and severity levels of discontinuities in aluminum fusion welds that may be revealed by radiographic examination. These reference radiographs do not specify the acceptable level of these discontinuities, rather they provide a visual reference...
5.1 Because of its simplicity and accuracy, the polarization resistance technique has been widely used in the laboratory in numerous metal/electrolyte systems (2, 7-10). However, its application in real-size elements is not straightforward because of the need for referral to the actual polarized...
5.1 In the absence of water, the crude oil is noncorrosive. However, trace amounts of water and sediment have the potential to create corrosive situations during crude oil handling or transport if such materials accumulate and persist on steel surfaces. Test Methods D473 and D4006 provide methods...
5.1 This test method is suitable for research or for quality control to characterize TDI and MDI. 5.2 This test method was developed to overcome problems with low-level acidity determinations that use glass electrodes in the presence of reagent alcohol solvents. Reagent alcohols contain...
5.1 Corrosion inhibitors continue to play a key role in controlling internal corrosion associated with oil and gas production and transportation. This results primarily from the industry's extensive use of carbon and low alloy steels, which, for many applications, are economic materials of...
1.1 This test method covers the determination of wear metals and contaminants in used industrial oils by sweeping flat electrode atomic emission spectroscopy (SFE-AES). 1.2 Industrial oil includes lubricant oil, gear box oil, hydraulic fluid, compressor oil, turbine oil, synthetic oils, and...
4.1 Corrosion film growth with thicknesses varying from a monolayer of atoms up to 1 μm can readily be measured on a continuous, real-time, in-situ, basis with QCMs. 4.2 The test results obtained for this test method are influenced by various factors, including geometrical effects, temperature,...
4.1 Corrosion film growth with thicknesses varying from a monolayer of atoms up to 1 μm can readily be measured on a continuous, real-time, in-situ, basis with QCMs. 4.2 The test results obtained for this test method are influenced by various factors, including geometrical effects, temperature,...
5.1 The capability of this test method to collect and quantitate both particulate and gaseous fluorides over the ranges normally encountered in industrial atmospheres makes it applicable for industrial hygiene evaluation and control purposes. The recommended range of this test method for fluoride...
5.1 General corrosion is characterized by areas of greater or lesser attack, throughout the plant, at a particular location, or even on a particular probe. Therefore, the estimation of corrosion rate as with mass loss coupons involves an averaging across the surface of the probe. Allowance must be...
1.1 This practice covers the testing of the performance of a flame ionization detector (FID) used as the detection component of a gas or supercritical fluid (SF) chromatographic system. 1.2 This recommended practice is directly applicable to an FID that employs a hydrogen-air or hydrogen-oxygen...
1.1 This test method covers the determination of contaminants and materials as a result of corrosion in gas turbine or diesel engine fuels by rotating disc electrode atomic emission spectroscopy (RDE-AES). 1.1.1 The test method is applicable to ASTM Grades 0-GT, 1-GT, 2-GT, 3-GT, and 4-GT...
Narrow Your Results