ASTM C1289-23a - Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board
September 1, 2023 - ASTM International

1.1 This specification covers the general requirements for faced thermal insulation boards composed of rigid cellular polyisocyanurate surfaced with other materials. The insulation boards are intended for use at temperatures between?-40 and 200°F (-40 and 93°C). This specification...

ASTM C1303/C1303M-11a - Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation
May 15, 2011 - ASTM International

Rigid gas-filled closed-cell foam insulations include all cellular plastic insulations which rely on a blowing agent (or gas), other than air, for thermal resistance values. At the time of manufacture, the cells of the foam usually contain their highest percentage of...

ASTM C1534-20a - Standard Specification for Flexible Polymeric Foam Sheet Insulation Used as a Thermal and Sound Absorbing Liner for Duct Systems
May 15, 2020 - ASTM International

This specification covers the composition, dimensions, and physical properties of flexible unfaced foam sheet, used to insulate interior surfaces of HVAC ducts, plenums and equipment used for the distribution of conditioned air. The flexible polymeric insulations of this specification...

ASTM C950/C950M-08(2023) - Standard Practice for Repair of a Rigid Cellular Polyurethane Insulation System on Outdoor Service Vessels
March 1, 2023 - ASTM International

1.1 This practice covers the repair of spray-applied polyurethane insulation on vessels normally operating at temperatures between?-30 and?+107°C [-22 and?+225°F]. 1.2 Warning-At temperatures below 0°C [32°F] the application of a spray "foam" directly onto the cold substrate may not...

BS ISO 21844 - Cellular plastic — Cellulose foam thermal insulation — Material specification
May 31, 2018 - BSI
A description is not available for this item.
BS EN 17333-5 - Characterisation of one component foam Part 5: Insulation
March 31, 2020 - BSI
A description is not available for this item.
ASTM C1534-20 - Standard Specification for Flexible Polymeric Foam Sheet Insulation Used as a Thermal and Sound Absorbing Liner for Duct Systems
May 1, 2020 - ASTM International

This specification covers the composition, dimensions, and physical properties of flexible unfaced foam sheet, used to insulate interior surfaces of HVAC ducts, plenums and equipment used for the distribution of conditioned air. The flexible polymeric insulations of this specification...

ISUZU ISC-C92-026 - Flexible-polyurethane foam for noise insulation
January 1, 2016 - ISUZU

This standard covers the cellular flexible-polyurethane foam products for noise insulation and the parts for engine noise control made of these products.

ASTM C1303/C1303M-12 - Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation
March 1, 2012 - ASTM International

Rigid gas-filled closed-cell foam insulations include all cellular plastic insulations which rely on a blowing agent (or gas), other than air, for thermal resistance values. At the time of manufacture, the cells of the foam usually contain their highest percentage of...

ASTM C1303/C1303M-11 - Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation
March 1, 2011 - ASTM International

Rigid gas-filled closed-cell foam insulations include all cellular plastic insulations which rely on a blowing agent (or gas), other than air, for thermal resistance values. At the time of manufacture, the cells of the foam usually contain their highest percentage of...

ASTM C1482-23 - Standard Specification for Polyimide Flexible Cellular Thermal and Sound Absorbing Insulation
March 1, 2023 - ASTM International

1.1 This specification covers the composition and physical properties of lightweight, flexible open-cell polyimide foam insulation intended for use as thermal and sound-absorbing insulation for temperatures from -328°F up to +572°F (-200°C and +300°C) in commercial and...

ASTM C1289-23 - Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board
May 1, 2023 - ASTM International

1.1 This specification covers the general requirements for faced thermal insulation boards composed of rigid cellular polyisocyanurate surfaced with other materials. The insulation boards are intended for use at temperatures between?-40 and 200°F (-40 and 93°C). This specification...

ASTM C1303/C1303M-10 - Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation
June 1, 2010 - ASTM International

Rigid gas-filled closed-cell foam insulations include all cellular plastic insulations which rely on a blowing agent (or gas), other than air, for thermal resistance values. At the time of manufacture, the cells of the foam usually contain their highest percentage of...

GMKOREA EDS-M-6676 - High Hysteresis Foam for Insulation
June 1, 2011 - GMKOREA

Sound isolator and sound absorber for floor panel and inner dash panel PURPOSE This standard specifies the physical properties and controlling quality of the high hysteresis foam (hereinafter called "HHF") that is used as the sound isolator and sound absorber.

ASTM C1303 - Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation
December 1, 2009 - ASTM

This test method covers a procedure for predicting the long-term thermal resistance (LTTR) of unfaced or permeably faced rigid gas-filled closed-cell foam insulations by reducing the specimen thickness to accelerate aging under controlled laboratory conditions (1-5) .2 Rigid...

ASTM C1303-09a - Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation
December 1, 2009 - ASTM International

Rigid gas-filled closed-cell foam insulations include all cellular plastic insulations which rely on a blowing agent (or gas), other than air, for thermal resistance values. At the time of manufacture, the cells of the foam usually contain their highest percentage of...

ASTM C1303-09 - Standard Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation
November 1, 2009 - ASTM International

Rigid gas-filled closed-cell foam insulations include all cellular plastic insulations which rely on a blowing agent (or gas), other than air, for thermal resistance values. At the time of manufacture, the cells of the foam usually contain their highest percentage of...

ASTM C1534 - Standard Specification for Flexible Polymeric Foam Sheet Insulation Used as a Thermal and Sound Absorbing Liner for Duct Systems
May 15, 2020 - ASTM

This specification covers the composition, dimensions, and physical properties of flexible unfaced foam sheet, used to insulate interior surfaces of HVAC ducts, plenums and equipment used for the distribution of conditioned air with a temperature of up to 250°F (121°C). HVAC ducts, plenums...