Summarises BRE Report BR 113 'Steel-framed and steel-clad houses: Inspection and assessment'.
Offers up-to-date guidance on how to assess the significance of key observations and measurements gathered during the detailed examinations recommended in GBG 11 and how to identify any need for remedial work.
Supplements initial inspection procedure by suggesting what further information should be gathered by surveyors when deficiencies related to structural stability, durability or fire protection are suspected. (Guidance on the interpretation of information collected is given in GBG 12.)
Presents the findings of the effects of holes behind intact plaster board lining.
NOTE: This guide specification covers the requirements for framing components and erection of load-bearing cold-formed metal framing and trusses.
본 규격은 자동차의 FRONT BODY PILLAR INNER와 W/HOUSE REAR, FRAME DR OPG와 PLR INNER등의 접착과 SEALING에 사용한다.
NOTE: This guide specification covers the requirements for steel joist framing and accessories and includes the following components: Open Web Steel Joists (K-Series and KCS), Longspan Steel Joists (LH-Series), Deep Longspan Steel Joists (DLH-Series), Joist Girders, Composite Steel Joists...
Examines the effects of different types of occupancy on the moisture levels within the external walls of timber-framed houses.
Material Description A staggered-truss frame is designed with steel framing members and concrete floors. Most often, the floor system is precast concrete hollow-core plank. Other options, including concrete supported on metal deck with steel beams or joists, can be used. With precast...
FRS has examined the fire behaviour of three types of breather membrane for use in timber-framed houses to find out if a serious fire could result from their ignition. The author establishes implications from the results of the research.
FRS has examined the fire behaviour of three types of breather membrane for use in timber-framed houses to find out if a serious fire could result from their ignition. The author establishes implications from the results of the research.
Material Description. Sealer based on butyl rubber and hot melt as phenol resin basis. Optional Material. 94545164(M-8546) is mutually capable of using 94545163(M-8545) or 94545165(M-8547). Typical Applications. This specification specifies the general requirement of tape sealer for adhesion and...
Second of a three-part Digest giving brief guidance on the use of BS 6399-2. Part 1 gives advice and guidance on implementing BS 6399-2 and suggests certain options. This Part demonstrates the recommended options by example calculations for the case of a two-storey timber framed house...
With any building material or product, sound construction and installation practices must be followed to assure durability and trouble-free performance. Areas for economy in basic design and house construction are covered in numerous publications. However, skimping on materials or using poor...