1.1 These reference radiographs illustrate various categories, types, and severity levels of discontinuities occurring in tin bronze and related alloy castings. The reference radiograph films are an adjunct to this document and must be purchased separately from ASTM International if needed (see 2...
1.1 These digital reference images illustrate various categories, types, and severity levels of discontinuities occurring in tin bronze and related alloy castings. The digital reference images are an adjunct to this document and must be purchased separately from ASTM International if needed (see...
1.1 This practice covers the nondestructive testing of field seams in geomembranes using the spark test. A suspect area is indicated by the generation of a spark. The test is applicable to seams made by the extrusion method, seams made by using welding tape (a strip of the same type of material as...
1.1 This terminology covers definitions of technical terms used in the rubber industry. Terms that are generally understood or adequately defined in other readily available sources are not included. 1.2 Definitions for terms that have been established by other bodies recognized as expert in the...
This specification covers a disposable glass Westergren tube used for measuring the erythrocyte sedimentation rate. Covered by this specification are Type I (standard Westergren tube used in conventional racks only) and Type II (self-zeroing tubes used with racks that have convenient disposable...
1.1 These reference radiographs illustrate various categories, types, and severity levels of discontinuities occurring in steel castings that have section thicknesses of 2?in. to less than 41/2 in. (50.8?mm to 114 mm). The reference radiograph films are an adjunct to this document and must be...
1.1 These reference radiographs illustrate various categories, types, and severity levels of discontinuities occurring in steel castings that have section thicknesses of 41/2 in. to 12?in. (114?mm to 305 mm). The reference radiograph films are an adjunct to this document and must be purchased...
1.1 These reference radiographs illustrate various categories, types, and severity levels of discontinuities occurring in steel castings that have section thicknesses up to 2 in. (50.8 mm) (see Note 2). The reference radiograph films are an adjunct to this standard and must be purchased separately...
This specification outlines the basic performance requirements and corresponding test methods for barrel blocking devices used in the sport of air soft. It covers air soft gun barrel blocking devices that may be inserted or otherwise function to prevent an airsoft projectile from leaving the...
This specification covers stainless steel clamps for securing SDR9 cross-linked polyethylene (PEX) tubing to metal insert and plastic insert fittings. All performance tests shall be performed on assemblies of fittings, clamps and PEX tubing. Clamps shall meet the material and...
4.1 This practice is a guideline for a short-term screening test for the evaluation of the tissue response to materials that may be selected for implantation in the human body and should be done in accordance with good laboratory practices. This test may be performed prior to long-term testing (for...
5.1 Cooking can be one of the most polluting activities commonly and regularly occurring in residential environments. Capturing airborne cooking contaminants before they can mix with the indoor air is a critical indoor air quality control method. 5.2 Range hoods are used in homes to remove...
This specification covers metal insert fittings and copper crimp rings for use with SDR9 cross-linked polyethylene (PEX) tubing. All performance tests shall be performed on assemblies of fittings, crimp rings, and PEX tubing. Fittings and crimp rings shall meet the material and dimensional...
This specification covers a rigid wall, nonexpendable shelter constructed of aluminum-faced, nonmetallic honeycomb sandwich panels. Electrical continuity testing, water leakage and operational testing, performance testing, paint adhesion testing, packaging examination, thermal shock test, panel...
1.1 These test methods cover four procedures for determination of the permeability [relative permeability] of materials having a relative permeability not exceeding 6.0. 1.2 The test methods covered are as follows: 1.2.1 Test Method 1-Fluxmetric Method is suitable for materials with relative...
1.1 This specification defines those characteristics that are required of adhesives to be used in the repair of sandwich panels for durable, rigidwall, relocatable structures. 1.1.1 This specification covers two-part epoxy adhesive suitable for bonding aluminum alloy facings to nonmetallic core,...
1.1 This is a fire-test-response standard. 1.2 This test method covers a means of measuring mass loss and fire behavior (and, optionally, smoke obscuration), from mattresses intended for detention or correctional facilities, by igniting the mattress, or mattress insert, with sheets of...
This specification covers metal insert fittings and copper crimp rings for use with SDR9 cross-linked polyethylene (PEX) tubing. All performance tests shall be performed on assemblies of fittings, crimp rings, and PEX tubing. Fittings and crimp rings shall meet the material and dimensional...
This specification covers standards for minimum-wall-thickne
1.1 This test method covers determination of the pullout strength of hardened concrete by measuring the force required to pull an embedded metal insert and the attached concrete fragment from a concrete test specimen or structure. The insert is either cast into fresh concrete or...
Narrow Your Results