As the leading authority on ammonia refrigeration, the International Institute of Ammonia Refrigeration developed the Ammonia Refrigeration Management (ARM) Program to help small facilities improve safety, enhance system reliability and assist with regulatory compliance. ARM is...
5.1 Before proceeding with these test methods, refer to the specification of the material being tested. Any test specimen preparation, conditioning, dimensions, and testing parameters covered in the materials specification shall take precedence over those mentioned in these test methods. If there...
1.1 This practice covers a split-force measurement apparatus (SFMA), a measurement system that uses split geometries and load cells to quantify the force of a grasp and external forces applied to an object under grasp. The SFMA supports a series of standard performance test methods for...
5.1 This guide can be used to develop test parameters for evaluating fatigue and wear behavior of IVD prostheses under impingement loading. It must be recognized, however, that there are likely many possible impingement conditions for a given IVD prosthesis. 5.2 The user should attempt to...
1.1 This practice describes "System" as a robotic, automatic, or autonomous system (for example, robot arm; automatic machine; automatic, automated, or autonomous?-?uncrewe
1.1 These test methods specify procedures and equipment used for testing and evaluating stationary exercise upright and recumbent bicycles and ergometers for compliance to Specification F1250. Both design and operational parameters will be evaluated. Where possible and applicable, accepted test...
1.1 This practice covers a split-force measurement apparatus (SFMA), a measurement system that uses split geometries and load cells to quantify the force of a grasp and external forces applied to an object under grasp. The SFMA supports a series of standard performance test methods for...
5.1 Before proceeding with these test methods, reference should be made to the specification of the material being tested. Any test specimen preparation, conditioning, dimensions, and testing parameters covered in the materials specification shall take precedence over those mentioned in these test...
4.1 A Rockwell hardness number is a number derived from the net increase in depth impression as the load on an indenter is increased from a fixed minor load to a major load and then returned to a minor load (Procedure A). A Rockwell alpha (a) hardness number represents...
5.1 Before proceeding with these test methods, reference should be made to the specification of the material being tested. Any test specimen preparation, conditioning, dimensions, and testing parameters covered in the materials specification shall take precedence over those mentioned in these test...
5.1 Before proceeding with these test methods, reference should be made to the specification of the material being tested. Any test specimen preparation, conditioning, dimensions, and testing parameters covered in the materials specification shall take precedence over those mentioned in these test...
1.1 This specification covers manually fed, motor-driven vertically oscillating arm type, automatically controlled, commercial pot, pan, and utensil washing machines, hereinafter referred to as "the washer." 1.2 The values stated in inch-pound units are to be regarded as standard. The values...
1.1 This practice provides ergonomic design criteria from a human-machine perspective for the design and construction of maritime vessels and structures and for equipment, systems, and subsystems contained therein, including vendor-purchased hardware and software. 1.1.1 The focus of these design...
1.1 This practice provides ergonomic design criteria from a human-machine perspective for the design and construction of maritime vessels and structures and for equipment, systems, and subsystems contained therein, including vendor-purchased hardware and software. 1.1.1 The focus of these design...
5.1 Spinal implants are generally composed of several components which, when connected together, form a spinal implant assembly. Spinal implant assemblies are designed to provide some stability to the spine while arthrodesis takes place. These test methods outline standard materials and methods for...
This International Standard specifies the design, minimum safety and functional requirements, inspection and testing procedures for LNG dry-disconnect/conne
This document establishes the terminology and content of commercial specifications for hydraulic breakers which are mounted as an attachment on a carrier, typically earth-moving machinery such as an excavator, backhoe loader, skid steer loader, and compact loader as defined in...
1.1 This specification covers flat-bottom, upright, cylindrical tanks molded in one-piece seamless construction by rotational molding. The tanks are molded from polyethylene for above ground, vertical installation and are capable of containing aggressive chemicals at atmospheric pressure. Included...
Narrow Your Results