1.1 This specification covers the evaluation of adhesives suitable for the bonding of oriented strand board (OSB) to rigid cellular polystyrene insulation core materials for general structure use. 1.2 The requirements of the structural insulated panel (SIP) adhesive are based on the...
1.1 These test methods cover the determination of the tensile properties of wood structural panels. 1.2 Wood structural panels in use include plywood, oriented strand board and composites of veneer, and other wood-based layers. 1.3 Test Method A, Tensile Test for Small...
1.1 This test method covers the determination of the quantity of water absorbed in a specified time through the surface of an overlaid wood-based panel. The test method measures the rate of water gain within a controlled surface area of the overlaid panel surface when exposed to...
This specification covers mineral fiber block and board thermal insulation. Mineral fiber board insulation covered by this specification shall be classified into types and categories; category 1 - no compressive resistance properties are required, category 2 - minimum compressive...
1.1 This specification covers the minimum requirements for and methods of application of exterior gypsum panel products that are specifically designed for use as a substrate for exterior cladding. 1.1.1 This specification does not cover gypsum panel products that are specifically...
This specification covers the general requirements for faced thermal insulation boards composed of rigid cellular polyisocyanurate surfaced with other materials. This standard is intended to apply to rigid cellular polyurethane-modifie
This specification covers fiber-reinforced gypsum panel. The physical properties, dimensions and tolerances, and edges of interior fiber-reinforced gypsum panels, water-resistant fiber-reinforced gypsum backing panels, exterior fiber-reinforced gypsum soffit panels,...
1.1 These test methods determine the flexural properties of strips cut from structural panels or panels up to 4?ft by 8 ft in size. Structural panels in use include plywood, waferboard, oriented strand board, and composites of veneer and of wood-based layers. Four...
This specification covers the glass mat gypsum panels. Glass mat interior gypsum panel, designed for use on walls, ceilings, or partitions and that affords a surface suitable to receive decoration. Glass mat coreboard gypsum panel, and glass mat shaftliner gypsum panel,...
4.1 Procedure A measures the ability of a pressure-sensitive tape to adhere to a standard steel panel under constant stress. This may or may not relate to the ability of the tape to adhere to other surfaces. 4.2 Procedures B, C, and D may be used to determine the shear adhesion of the tapes...
3.1 These methods determine the compressive strength of structural panels in response to stresses acting in the plane of the panel. 3.2 Method A-This method is applicable to structural panels of uniform properties within a panel. It is useful for evaluating plywood of...
1.1 This test method applies to the calibration of hand-held moisture meters for gypsum board, glass faced gypsum panels and fiber-reinforced gypsum panels by means of electrical conductance and dielectric meters. The test uses wetted test specimens which are dried down in at...
1.1 This specification covers faced or unfaced, rigid cellular phenolic thermal insulation. Boards shall be faced or unfaced. Tubular forms and board cut from a block or bun covered by this standard shall be unfaced. It does not apply to field expanded cellular phenolic materials. Note 1: If...
1.1 This practice covers the installation of suspended systems for acoustical tile and lay-in panels and their additional requirements for two groups of buildings that are constructed to resist the effects of earthquake motions as defined by ASCE 7 and the International Building Code. These...
This specification provides procedures for testing and establishing the structural capacities of proprietary rim board products and assemblies for use in light-frame wood construction using I-joist or structural composite lumber joist framing. This specification also establishes several...
3.1 Planar shear (rolling shear) characteristics of structural panels determined by these test methods are essential for the rigorous design of various glued wood-panel structural components, such as box beams, folded plate roofs, and stressed skin panels. Planar shear also may...
1.1 This test method shall be used to measure the relative corner impact resistance and other damage that may occur during the rough handling of wood-base panels or composite materials. This test method is suitable for all wood-base panels such as plywood, oriented strand...
1.1 This specification covers discrete fiber-cement sheets manufactured to be dimensionally stable and suitable for decoration as paint, wallpaper, natural stone, tile, or resilient flooring in internal wet and dry areas. 1.2 This specification is not applicable to fiber-cement flat sheets for...