loading
MIL-T-28732 - TRANSFORMER, IMPEDANCE MATCHING, BALANCE TO UNBALANCE (BALUN)
NPFC
A description is not available for this item.
MIL-T-28767 - TRANSFORMER, IMPEDANCE MATCHING (BALUN), RECEIVE ONLY
NPFC
A description is not available for this item.
Power Transformer Design Practices
March 19, 2021 - CRC

The book presents basic theories of transformer operation, design principles and methods used in power transformer designing work, and includes limitation criteria, effective utilization of material, and calculation examples to enhance readers' techniques of transformer...

IEEE 389 - Recommended Practice for Testing Transformers and Inductors for Electronics Applications
March 5, 2020 - IEEE

This recommended practice presents a number of tests for use in determining the significant parameters and performance characteristics of electronics transformers and inductors. These tests are designed primarily for transformers and inductors used in all types of electronics...

NEMA TP 2 - Standard Test Method for Measuring the Energy Consumption of Distribution Transformers
January 1, 2005 - NEMA

Provides the basis for determining the energy efficiency of single- and three-phase dry-type and liquid-immersed distribution transformers and assists with the proper selection of such equipment. This standard is intended for use as a basis for determining the energy efficiency performance...

IEEE 844.3 - IEEE/CSA Standard for Impedance Heating of Pipelines and Equipment— General, Testing, Marking, and Documentation Requirements
February 8, 2019 - IEEE

This standard applies to general, testing, marking, and documentation requirements for impedance heating systems for steel or steel alloy pipe or equipment, rated up to and including 132 Vac. These heating system components are intended for installation in accordance with CSA C22.1, Canadian...

CSA C22.2 NO 293.3 - IEEE/CSA Standard for Impedance Heating of Pipelines and Equipment— General, Testing, Marking, and Documentation Requirements
January 1, 2019 - CSA

This standard applies to general, testing, marking, and documentation requirements for impedance heating systems for steel or steel alloy pipe or equipment, rated up to and including 132 Vac. These heating system components are intended for installation in accordance with CSA C22.1, Canadian...

Transformer Design Principles
August 22, 2017 - CRC

In the newest edition, the reader will learn the basics of transformer design, starting from fundamental principles and ending with advanced model simulations. The electrical, mechanical, and thermal considerations that go into the design of a transformer are discussed with useful...

ASME PTC 19.6 - Electrical Power Measurements
August 6, 2018 - ASME

The methods given herein include direct and indirect determinations of active power (watts), reactive power (vars), and power factor produced or consumed in alternating-current single-phase and polyphase electrical circuits, electrical generators, power...

RF and Microwave Power Amplifier Design, Second Edition
January 1, 2015 - MCGRAW

The latest power amp design methods. Fully updated to address cutting-edge technologies, the new edition of this practical guide provides comprehensive, state-of-the-art coverage of RF and microwave power amplifier design. The book describes both existing and new schematic...

IEC 61007 - Transformers and inductors for use in electronic and telecommunication equipment – Measuring methods and test procedures
July 1, 2020 - IEC

This document describes a number of tests for use in determining the significant parameters and performance characteristics of transformers and inductors for use in electronics and telecommunication equipment. These test methods are designed primarily for transformers and inductors...

MIL-P-13108 - PUBLIC ADDRESS SETS AN/UIQ-1( ) AND AN/UIQ-3( ) (COMPONENTS FOR)
November 6, 1953 - NPFC

This specification covers the following components of Public Address Sets AN-UIQ-1( ) and AN-UIQ-3( ), which are high powered, transportable, public address equipments used to address large groups of men dispersed over wide areas or under adverse conditions; for example: To address,...

DSF/PREN IEC 61007 - Transformers and inductors for use in electronic and telecommunication equipment – Measuring methods and test procedures
DS

This standard describes a number of tests for use in determining the significant parameters and performance characteristics of transformers and inductors for use in electronics and telecommunication equipment. These test methods are designed primarily for transformers and inductors...

NG TGN(T) 064 - Technical Guidance Notes - Instantaneous High-Impedance Protection
January 1, 1995 - NG

This TGN gives guidance on the considerations, calculations, and proving of instantaneous highimpedance differential protection systems as applied to busbars, transformers, reactors, capacitors, synchronous machines and similar primary plant connections. Unless stated otherwise, the rms...

UL 1411 - Transformers and Motor Transformers for Use in Audio-, Radio-, and Television-Type Appliances
January 15, 2016 - ULSE

Transformers and Motor Transformers for Use in Audio-, Radio-, and Television-Type Appliances UL 1411 1.1 These requirements apply to transformers, autotransformers, and motor-transformers intended to be used in audio-, radio-, and television-type appliances in which the...

DS/EN IEC 61007 - Transformers and inductors for use in electronic and telecommunication equipment – Measuring methods and test procedures
September 8, 2020 - DS

IEC 61007:2020 describes a number of tests for use in determining the significant parameters and performance characteristics of transformers and inductors for use in electronics and telecommunication equipment. These test methods are designed primarily for transformers and inductors...

CSA C22.2 NO 66.3 - Low Voltage Transformers — Part 3: Class 2 and Class 3 Transformers
January 1, 2006 - CSA

As noted in Low Voltage Transformers - Part 1: General Requirements, UL 5085-1, or CSA C22.2 No. 66.1, Low Voltage Transformers - Part 1: General Requirements, the requirements in Part 3 cover Class 2 transformers for use with Class 2 circuits in accordance with the National...

UL 5085-3 - Low Voltage Transformers - Part 3: Class 2 and Class 3 Transformers
April 17, 2006 - ULSE

1.1 As noted in Low Voltage Transformers - Part 1: General Requirements, UL 5085-1, or CSA C22.2 No. 66.1, Low Voltage Transformers - Part 1: General Requirements, the requirements in Part 3 cover Class 2 transformers for use with Class 2 circuits in accordance with the...

IEEE C93.4 - Power-Line Carrier Line-Tuning Equipment (30 kHz to 500 kHz) Associated with Power Transmission Lines
December 5, 2012 - IEEE

This standard applies to power-line carrier (PLC) line-tuning equipment connected between the coupling capacitors and PLC transmitter/receiver terminals operating in the frequency range of 30 kHz to 500 kHz over power transmission lines and cables or to similar line-tuning equipment...

IEEE 390 - Standard for Pulse Transformers
December 11, 1986 - IEEE

This standard pertains to pulse transformers for use in electronic equipment. For the various types of these transformers, the peak power transmitted ranges from a few milliwatts to kilowatts; and the peak voltage transmitted ranges from a few volts to many kilovolts. These...

Advertisement