loading
GMW14727 - Rubber Sealings for Refrigerant Applications
October 1, 2019 - GMW

This standard covers the materials and performance requirements of Ethylene Propylene Diene Monomer (EPDM) and Hydrogenated Nitrile Butadiene Rubber (HNBR) O-rings and slim line seal washers used for sealing in Air Conditioning (A/C) systems with liquid and gaseous refrigerant. Rubber...

IEC 60335-2-34 REDLINE - Household and similar electrical appliances – Safety – Part 2-34: Particular requirements for motor-compressors
March 1, 2021 - IEC

This part of IEC 60335 deals with the safety of sealed (hermetic and semi-hermetic type) motor-compressors, their protection and control systems, if any, which are intended for use in equipment for household and similar purposes and which conform with the standards applicable to such equipment. It...

IEC 60335-2-34 - Household and similar electrical appliances – Safety – Part 2-34: Particular requirements for motor-compressors
March 1, 2021 - IEC

This part of IEC 60335 deals with the safety of sealed (hermetic and semi-hermetic type) motor-compressors, their protection and control systems, if any, which are intended for use in equipment for household and similar purposes and which conform with the standards applicable to such equipment. It...

DS/EN 378-1 - Refrigerating systems and heat pumps – Safety and environmental requirements – Part 1: Basic requirements, definitions, classification and selection criteria
November 2, 2020 - DS

This European Standard specifies the requirements for the safety of persons and property, provides guidance for the protection of the environment and establishes procedures for the operation, maintenance and repair of refrigerating systems and the recovery of refrigerants. The term...

ISO 8066-3 - Rubber and plastics hoses and hose assemblies for automotive air conditioning — Specification — Part 3: Refrigerant 1234yf
August 1, 2020 - ISO

This document specifies the requirements for rubber or thermoplastic hoses and hose assemblies used for circulating liquid and gaseous R1234yf (tetrafluoropropene) in the air-conditioning systems of automobiles. The hoses and hose assemblies are designed in such a way as to restrict losses of...

ISO 21978 - Heat pump water heater — Testing and rating at part load conditions and calculation of seasonal coefficient of performance for space heating
February 1, 2021 - ISO

The document specifies test conditions for determining the seasonal performance characteristics of air source heat pump water heaters for space heating with electrically driven compressors with or without supplementary heater. The purpose of this document is to rate performance of the heat pump...

ASHRAE STD 225 - Method for Performance Testing Centrifugal Refrigerant Compressors and Condensing Units
January 1, 2020 - ASHRAE

This standard applies to centrifugal refrigerant compressors and condensing units using any refrigerants. This standard applies to single and multistage compressors with or without means of intermediate cooling. PURPOSE This standard provides methods of testing for the performance...

QPL-VV-L-825 - LUBRICATING OIL, REFRIGERANT COMPRESSOR, UNINHIBITED
November 18, 2019 - NPFC

QUALIFIED PRODUCT LIST OF PRODUCTS QUALIFIED UNDER PERFORMANCE SPECIFICATION VV-L-825 LUBRICATING OIL, REFRIGERANT COMPRESSOR, UNINHIBITED This list has been prepared for use by or for the Government in the acquisition of products covered by the subject specification and such listing of a...

NAVISTAR MPAPS B-41 - Refrigerant for Vehicle Air-Conditioning Systems
July 1, 2020 - NAVISTAR
A description is not available for this item.
GMW18235 - Refrigerant Plumbing Hose Coupling Assemblies Validation Testing
July 1, 2020 - GMW
A description is not available for this item.
J1628_202011 - Technician Procedures for Refrigerant Leak Detection in Service of Mobile Air Conditioning Systems
November 30, 2020 - SAE International

This SAE Recommended Practice applies to the use, by automotive service technicians, of generally available leak detection methods to service motor vehicle passenger compartment air conditioning systems.

DS/EN 12115 - Rubber and thermoplastics hoses and hose assemblies for liquid or gaseous chemicals – Specification
January 25, 2021 - DS

This document specifies requirements for two types of hose assemblies (Types D and SD) and four grades based on electrical properties with hoses made of rubber or thermoplastics and hose fittings made of metal designed to convey liquid or gaseous chemical substances, hereinafter termed the...

DS/EN 378-3 - Refrigerating systems and heat pumps – Safety and environmental requirements – Part 3: Installation site and personal protection
November 2, 2020 - DS

This European Standard specifies the requirements for the safety of persons and property, provides guidance for the protection of the environment and establishes procedures for the operation, maintenance and repair of refrigerating systems and the recovery of refrigerants. The term...

ISO 23467 - Ice plug isolation of piping in nuclear power plant
November 1, 2020 - ISO

This document specifies requirements for the ice plug technique with liquid nitrogen or dry ice as refrigerant (cryogenic medium) on metal pipes of nuclear power plants. The freezing liquid can be water or water mixture (e.g. boric acid mixture). This document specifies technical...

9986181 - Synthetic Polyalkylene Glycol Lubricant
October 1, 2020 - GMNA

Material Description. This specification defines the minimum acceptable requirements for synthetic polyalkylene glycol (PAG) lubricants for use in GM mobile air conditioning systems designed for HFC-134a refrigerant. This specification applies only to PAG lubricants approved for use in...

J2773_202005 - Standard for Refrigerant Risk Analysis for Mobile Air Conditioning Systems
May 15, 2020 - SAE International

This SAE Standard describes methods to understand the risks associated with vehicle mobile air conditioning (MAC) systems in all aspects of a vehicle's lifecycle including design, production, assembly, operation, and end of life. Information for input to the risk assessment is provided in the...

ASHRAE STD 64 - Methods of Laboratory Testing Remote Mechanical-Draft Evaporative Refrigerant Condensers
January 1, 2020 - ASHRAE

This standard provides a method of laboratory testing for obtaining performance data of remote mechanical-draft evaporative refrigerant condensers, including the following: a. Definition of terms b. Specification of data to be recorded c. Calculation formulas d. Test limits and tolerances e....

GMW15786 - Air Conditioning Refrigerant Fitting Shipping Cap Specification
November 1, 2019 - GMW

Purpose. This standard describes requirements, performance, validation, and shipping requirements for shipping caps to be used on Air Conditioning (A/C) refrigerant fittings for automotive applications during shipment to GM Component and/or Vehicle Assembly Plants. The engineering test...

Advertisement