624460-000020-000000
4.1 This practice is to be used as a guide to classify water bodies for spill control systems. These classifications may be used in formulating standards for design, performance, evaluation, contingency and response planning, contingency and response plan evaluation, and standard practice for spill...
4.1 This practice is intended to be used by cannabis or hemp operators, or both, to establish good supplier lifecycle management practices. 4.1.1 Without proper oversight, the quality and reliability of supplied materials, equipment, parts, software, or services can degrade. This can create...
1.1 This guide describes a methodology to select tests to be used for in-service lubricant analysis. The selection of fluid tests for monitoring failure mode progression in industrial applications applies the principles of failure mode and effect analysis (FMEA). 1.2 Although typical FMEA addresses...
5.1 Palladium and gold coatings are often specified for the contacts of separable electrical connectors and other devices. Electrodeposits are the form of gold that is most used on contacts, although it is also employed as inlay or clad metal and as weldments on the contact surface. The intrinsic...
4.1 The Eco-RBCA process presented in this guide is a streamlined decision-making process for implementing corrective action protective of ecological resources at chemical release sites in a consistent manner. Eco-RBCA provides a framework for sites not covered under regulatory programs, for sites...
5.1 Gold coatings are often specified for the contacts of separable electrical connectors and other devices. Electrodeposits are the form of gold that is most used on contacts, although it is also employed as clad metal and as weldments on the contact surface. The intrinsic nobility of gold enables...
1.1 This classification covers matched sets of scales for classifying an aspect of the serviceability of an office facility, that is, the capability of an office facility to meet certain possible requirements for performance to support typical office equipment for information technology. 1.2 Within...
5.1 This practice may be used to characterize silica or silane in terms of specific properties of the standard compound. This practice is useful for the quality assurance of silica production. It may also be used for the preparation of reference compounds for compounding experiments, to confirm the...
The landing gear system is a major and safety critical airframe system that needs to be integrated efficiently to meet the overall aircraft program goals of minimizing the penalties of weight, cost, dispatch reliability and maintenance. As the landing gear system business develops and...
1.1 This guide covers information for incorporating activity and use limitations that are protective of human health and the environment into federal, state, tribal or local remediation programs using a risk-based approach to corrective action. Activity and use limitations should be considered...
1.1 This test method covers the measurement of the total moisture in coal as it exists at the site, at the time, and under the conditions it is sampled. It is applicable to coals as mined, processed, shipped, or used in normal commercial pursuits. It is not applicable to coal-water slurries,...
4.1 This guide is relevant to the design of specialized support equipment and tools that are remotely operated, maintained, or viewed through shielding windows, or combinations thereof, or by other remote viewing systems. 4.2 Hot cells contain substances and processes that may be extremely...
4.1 The objective of this practice is to provide ergonomic design criteria for maritime vessels and structures to ensure that maritime systems and equipment are designed in compliance with requirements for human performance, human workload, health and safety, survivability, and habitability. 4.2...
5.1 Factors governing selection of a method for the determination of plutonium include available quantity of sample, sample purity, desired level of reliability, and equipment. 5.1.1 This test method determines 5?mg to 20 mg of plutonium with prior dissolution using Practice C1168. 5.1.2...
4.1 The purpose of this guide is to provide general guidelines for the design and operation of hot cell equipment to ensure longevity and reliability throughout the period of service. 4.2 It is intended that this guide record the general conditions and practices that experience has shown is...
The purpose of this procedure is to establish a technique for reliably and repeatedly measuring the RF shielding characteristics of EMI gasket materials and EMI gaskets against various joint surfaces. The procedure is also used to test the reliability of the gasketed joint combinations after...
The scope of this document is to discuss the differences between electromechanical and proximity position sensing devices (sensor or switch) when used on landing gear. It also contains information which may be helpful when applying either type of technology after the selection has been made. The...
5.1 Factors governing selection of a method for the determination of uranium include available quantity of sample, homogeneity of material sampled, sample purity, desired level of reliability, and facility available equipment. 5.2 This uranium assay method is referenced in the Test Methods...
This guide deals with the selection of the appropriate leak testing method for either leak measurement or location for a particular system being tested (test system), which may consist either of open units or sealed units. The leak testing method may either be dynamic or static, with the dynamic...