loading
IEC 62680-2-1 - Universal serial bus interfaces for data and power – Part 2-1: Universal Serial Bus Specification, Revision 2.0
September 1, 2015 - IEC

INTRODUCTION The IEC 62680 series is based on a series of specifications that were originally developed by the USB Implementers Forum (USB-IF). These specifications were to submitted to the IEC under the auspices of a special agreement between the IEC and the USB IF. The USB Implementers Forum, Inc...

W-C-596 - CONNECTOR, ELECTRICAL, POWER, GENERAL SPECIFICATION FOR
June 2, 2017 - NPFC

This specification covers electrical plugs, receptacles, and cable outlets for service from 120 to 600 volts with current ratings up to 60 amperes and a frequency rating of 50/60 hertz. It does not cover devices for use in hazardous locations as defined in the National Electrical Code. Special...

ASTM B794-97(2020) - Standard Test Method for Durability Wear Testing of Separable Electrical Connector Systems Using Electrical Resistance Measurements
October 1, 2020 - ASTM International

1.1 This test method covers the effects of repeated insertion and withdrawal of separable electrical connectors which are harmful to the electrical performance of the connector. 1.2 This test method is limited to electrical connectors designed for use in applications where the...

AS85049 - Connector Accessories, Electrical General Specification For
August 1, 1998 - SAE International

This specification covers connector accessories for use with electrical connectors under environmental or non-environmental conditions. Applicable connector accessories defined in this specification are delineated for the suppression of Electromagnetic Interference (EMI) and...

USCAR19-2 - COAXIAL CABLE CONNECTOR INTERFACE - SQUARE OUTER CONDUCTOR
August 5, 2021 - SAE International

This radio frequency (RF) connector interface specification is suited for unsealed automobile applications up to 2 GHz. Dimensional requirements are specified in this document to ensure interchangeability. This RF connector interface specification is intended for in-line, board mount,...

USCAR2-7 - PERFORMANCE SPECIFICATION FOR AUTOMOTIVE ELECTRICAL CONNECTOR SYSTEMS
February 3, 2020 - SAE International

Procedures included within this specification are intended to cover performance testing at all phases of development, production, and field analysis of electrical terminals, connectors, and components that constitute the electrical connection systems in low voltage (0 to 20 VDC) road vehicle...

USCAR2-8 - PERFORMANCE SPECIFICATION FOR AUTOMOTIVE ELECTRICAL CONNECTOR SYSTEMS
June 30, 2022 - SAE International

This specification covers performance testing at all phases of development, production, and field analysis of electrical terminals, connectors, and components that constitute the electrical connection systems in road vehicle applications that are: low voltage (0 to 20 VDC) or Coaxial....

NR NB 108 - BR985 LC Barrier Power Pack 'Connector
April 1, 2011 - NR

This NB covers standard BR843 Level Crossing Barriers. The advice applies to staff responsible for installing and/or maintaining the BR985 barrier power pack and BR843 Level Crossing Barrier Machine. Purpose This Notice Board is required to brief the introduction of the replacement BR985 LC Barrier...

JASO E208 - Liquefied Petroleum Gas Vehicles - Refuelling Connector
January 1, 2015 - JSAE

This standard specifies the refuelling connectors of liquefied petroleum gas vehicles with design pressure from 1.74 to 2.28 MPa.

VITA 86 - High Voltage Input Sealed Connector Power Supply
January 1, 2019 - VITA

CATS Abstract: This standard defines an environmentally sealed connector pair which is compatible with the backplane footprint as defined in VITA 62.0 for 3U power supplies operating in harsh environments operating off of a high voltage input.

J3138_202210 - Diagnostic Link Connector Security
October 4, 2022 - SAE International

This document describes a set of recommended actions to take to increase the likelihood of safe vehicle operation when a device (external test equipment, data collection device, etc.) whose normal operation has been compromised by a source external to the vehicle is connected to the vehicle's...

ASTM F962-04(2010) - Standard Specification for Oil Spill Response Boom Connection: Z-Connector
April 1, 2010 - ASTM International

The general design geometry herein defined applies to both a separate adaptor accessory mating two booms of different geometry as well as boom end connectors (see Terminology F818). Interconnectibility is intended to facilitate mating of oil spill response booms of various sizes, strengths,...

NEMA TS 2 - Traffic Controller Assemblies with NTCIP Requirements
January 1, 2016 - NEMA

NEMA TS 2 covers traffic signaling equipment used to facilitate and expedite the safe movement of pedestrians and vehicular traffic. Two approaches to expansion of traffic features of NEMA TS 1, Traffic Control Systems, are provided: 1. Type 1: Entirely new performance oriented standard. 2. Type 2:...

DS/EN 50077 - Low-profile connector for implantable cardiac pacemakers
February 14, 1996 - DS

This European standard specifies a connector assembly to be used to connect implantable pacemaker leads to implantable pulse generators. Essential dimensions and performance requirements are specified, together with appropriate test methods. However, this standard does not address all...

J2030_201506 - Heavy-Duty Electrical Connector Performance Standard
June 4, 2015 - SAE International

This SAE Standard encompasses connectors between two cables or between a cable and an electrical component and focuses on the connectors external to the electrical component. This document provides environmental test requirements and acceptance criteria for the application of...

ASTM F962-04 - Standard Specification for Oil Spill Response Boom Connection: Z-Connector
November 1, 2004 - ASTM International

This specification covers design criteria requirements, design geometry, material characteristics, and desirable features for oil spill response boom connections. These criteria are intended to define minimum mating characteristics and are not intended to be restrictive to a specific configuration....

AS34411A - CONNECTOR, PLUG, ELECTRIC, UTILITY
October 26, 2021 - SAE International
A description is not available for this item.
BS EN 24165 - Road Vehicles - Electrical Connections - Double-Pole Connector
April 1, 1992 - BSI

Characteristics of the double pole connector for special warning lights and for hand lamps.

MIL-DTL-38271 - CONNECTOR, OXYGEN MASK TO REGULATOR CRU-60/P
August 14, 2020 - NPFC

This specification covers one type of connector for connecting aircraft-panel-mounted oxygen regulator delivery tube and emergency oxygen cylinder assemblies to the oxygen demand breathing mask. The connector is designated CRU-60/P and is a Critical Safety Item (CSI).

ASTM B794-97(2015) - Standard Test Method for Durability Wear Testing of Separable Electrical Connector Systems Using Electrical Resistance Measurements
May 1, 2015 - ASTM International

1.1 This test method covers the effects of repeated insertion and withdrawal of separable electrical connectors which are harmful to the electrical performance of the connector. 1.2 This test method is limited to electrical connectors designed for use in applications where the...

Advertisement