1.1 This terminology consists of terms and definitions pertaining to the subject field of roofing and waterproofing, and in particular, terms related to standards generated by ASTM Committee D08 on Roofing and Waterproofing. 1.2 The purpose of this terminology is to provide preferred...
1.1 This terminology consists of terms and definitions pertaining to the subject field of roofing and waterproofing, and in particular, terms related to standards generated by ASTM Committee D08 on Roofing and Waterproofing. 1.2 The purpose of this terminology is to provide preferred...
1.1 This specification describes the required properties and test methods for a one or two-component, cold liquid-applied elastomeric-type membrane comprised of silyl-terminated polyether polymer, silyl-terminated polyurethane polymer, or a blend of the two polymers for waterproofing...
1.1 This test method covers the determination of low-temperature flexibility of liquid-applied membranes used in roofing and waterproofing. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be...
1.1 This specification covers prefabricated modified bituminous sheet materials reinforced with polyester fabric as the primary reinforcement, with or without granules, which use styrene butadiene styrene (SBS) thermoplastic elastomer as the primary modifier and are intended for use in the...
1.1 This guide describes the use of a high solids content, cold liquid-applied elastomeric waterproofing membrane that meets the criteria in Specification C836/C836M, in a waterproofing system subject to hydrostatic pressure for building decks over occupied space where the membrane is...
1.1 These test methods cover test procedures for prefabricated, reinforced, self-adhesive (SA) polymer-modified bituminous sheet materials designed for single- or multiple-ply application in roofing and waterproofing membranes. 1.2 These test methods specifically address the self-adhesive...
4.1 Establishing standard practices and recommended procedures is a critical step required to achieve quality roofing and waterproofing system installations. This guide describes preparing typical substrates to receive hot-applied rubberized asphalt (HRA), melting and application of HRA,...
1.1 This guide describes the selection of materials, installation methods, and inspection required for sealing leaks at cracks in concrete building walls and slabs using chemical grout. The process discussed in this guide is a waterproofing repair in which voids in a concrete element are...
4.1 This test method tests the hydrostatic resistance of a waterproofing membrane and can be used to compare the hydrostatic resistance of waterproofing membranes. It includes two specimen preparation procedures, one for post-applied membranes and one for pre-applied membranes. 4.2 No...
1.1 This specification describes the required properties and test methods for a one or two-component, cold liquid-applied elastomeric-type membrane comprised of silyl-terminated polyether polymer, silyl-terminated polyurethane polymer, or a blend of the two polymers for waterproofing...
1.1 This guide describes standard procedures for using electrical conductance measurement methods to locate leaks in exposed or covered roofing and waterproofing membranes. 1.2 This guide addresses the need for a general technical description of the current methods and procedures that are...
1.1 This specification covers polymer modified bituminous sheet materials intended for use as underlayment on roof eaves, or valleys, or both, to prevent leakage of shingle, tile, or metal roofs from water back-up due to ice dams. 1.2 These underlayment sheets have a sticky adhesive layer which is...
This specification covers asphalt-saturated organic felt used in roofing and waterproofing. Two types of asphalt-saturated felts are presented: type I - commonly called No. 15 asphalt felt, and type II - commonly called No. 30 asphalt felt. In the process of manufacture a single thickness of...
1.1 This specification describes the required properties and test methods for a cold liquid-applied elastomeric membrane for waterproofing building decks not subject to hydrostatic pressure. The specification applies only to a membrane system that has an integral wearing surface. This...
4.1 This guide provides the general information, procedures, and guidelines for the selection of the waterproofing membrane to create a waterproofing system for a vegetative (green) roof. 4.2 This guide is not all inclusive; this guide is intended to supplement detailed instructions...
1.1 This guide provides guidance and considerations related to designing sustainable low-sloped roofing systems, including exposed membrane roofs, membranes covered with landscaped and vegetative (green) overburden systems, ballasted roofs, and protected membrane roofing assemblies. A sustainable...
1.1 This guide describes the use of a high solids content, cold liquid-applied elastomeric waterproofing membrane that meets the criteria in Specification C836/C836M, in a waterproofing system subject to hydrostatic pressure for building decks over occupied space where the membrane is...
1.1 This test method covers a laboratory procedure for determining the ability of a waterproofing membrane to bridge a crack in the substrate. 1.2 There are no ISO standards similar or equivalent to this ASTM standard. 1.3 The values stated in either SI units or inch-pound units are to be...