This document specifies performance requirements for cathodic protection of steel in cement-based concrete, in both new and existing structures. It covers building and civil engineering structures, including normal reinforcement and prestressed reinforcement embedded in the concrete. It is...
ISO 12696:2016 specifies performance requirements for cathodic protection of steel in cement-based concrete, in both new and existing structures. It covers building and civil engineering structures, including normal reinforcement and prestressed reinforcement embedded in the concrete. It is...
This document specifies performance requirements for cathodic protection of steel in cement-based concrete, in both new and existing structures. It covers building and civil engineering structures, including normal reinforcement and prestressed reinforcement embedded in the concrete. It is...
This specification covers heavy vehicular paving bricks designed for use in streets, commercial driveways, aircraft taxiways, and other places where there is a high volume of heavy vehicular traffic. The bricks should be manufactured from clay, shale, or similar naturally occurring...
Inclusions This standard outlines methods of installing insulation products in common residential light-timber and steel-framed construction types. Information on the safe installation (clearances, health and safety) of insulating materials is appended. The detail in the standard is based on...
This specification covers heavy vehicular paving bricks designed for use in streets, commercial driveways, aircraft taxiways, and other places where there is a high volume of heavy vehicular traffic. The bricks should be manufactured from clay, shale, or similar naturally occurring...
3.1 This practice is used as a guide for the installation of chemical grout in the practice of sealing sewer manholes from leaks, cracks, and around penetrations. It is attended to assist sewer owners and engineer, owner's representative, or authorized inspectors for installation...
This specification covers heavy vehicular paving bricks designed for use in streets, commercial driveways, aircraft taxiways, and other places where there is a high volume of heavy vehicular traffic. The bricks should be manufactured from clay, shale, or similar naturally occurring...
4.1 Design professionals, for aesthetic reasons, have desired to limit the spacing and width of sealant joints on exterior walls and other locations of new buildings. Analysis of the performance factors and especially tolerances that affect a sealant joint is necessary to determine if a joint will...
4.1 Design professionals, for aesthetic reasons, have desired to limit the spacing and width of sealant joints on exterior walls and other locations of new buildings. Analysis of the performance factors and especially tolerances that affect a sealant joint is necessary to determine if a joint will...
Introduction and background Greenhouse gas reduction strategies, together with recent financial incentives such as the Carbon Emission Reduction Target (CERT) fund, Community Energy Saving Programme (CESP) and Energy Company Obligation (ECO), have resulted in a significant uptake in improvements to...
This specification covers heavy vehicular paving bricks designed for use in streets, commercial driveways, aircraft taxiways, and other places where there is a high volume of heavy vehicular traffic. The bricks should be manufactured from clay, shale, or similar naturally occurring...
This specification covers heavy vehicular paving bricks designed for use in streets, commercial driveways, aircraft taxiways, and other places where there is a high volume of heavy vehicular traffic. The bricks should be manufactured from clay, shale, or similar naturally occurring...
This specification covers heavy vehicular paving bricks designed for use in streets, commercial driveways, aircraft taxiways, and other places where there is a high volume of heavy vehicular traffic. The bricks should be manufactured from clay, shale, or similar naturally occurring...
This practice covers detailed information on the handling, installation, and proper use of chemical-resistant sulfur mortar. The sulfur mortar shall be stored in unopened containers and in a clean, dry place to prevent contamination of the product. Sulfur mortar must be heated and molten in...
This specification covers heavy vehicular paving bricks designed for use in streets, commercial driveways, aircraft taxiways, and other places where there is a high volume of heavy vehicular traffic. The bricks should be manufactured from clay, shale, or similar naturally occurring...
ul-2790.1 Commercial Incinerators UL 2790 1 Scope 1.1 These requirements apply to direct-fed incinerators, including those of the gas and electric ignition types, designed primarily for use as a crematory (as defined in 5.30). They are not intended to incinerate any hazardous, including...
Design professionals, for aesthetic reasons, have desired to limit the spacing and width of sealant joints on exterior walls and other locations of new buildings. Analysis of the performance factors and especially tolerances that affect a sealant joint is necessary to determine if a joint will have...
This practice is used as a guide for the installation of chemical grout in the practice of sealing sewer manholes from leaks, cracks, and around penetrations. It is attended to assist sewer owners and engineer, owner's representative, or authorized inspectors for installation method...
1.1 This practice provides detailed information on the handling, installation, and proper use of chemical-resistant sulfur mortar such as those covered in Specification C 287. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the...