loading
ISA TR18.2.7 - Alarm Management When Utilizing Packaged Systems
February 17, 2017 - ISA

General considerations This technical report provides guidance on how to integrate packaged systems (PSs) into a BPCS-based centralized alarm system. The scope includes discussing various issues that can arise when ISA-18.2 work processes are applied to facilities where PSs are used, and...

UFGS-28 31 76 - INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM
August 1, 2011 - ARMY

NOTE: This specification covers the requirements for an integrated fire detection, fire alarm evacuation and mass notification system.

UL 1638A - Visual Signal Appliances for General Signaling Use
June 22, 2016 - ULSE

01638a-000000-000000 1 Scope 1.1 These requirements cover electrically-operated visual signaling appliances, rated 300 volts or less, and intended for indoor locations, outdoor locations, or both, in accordance with the National Electrical Code, NFPA 70. 1.2 These requirements cover visual...

CEI EN 62241 - Nuclear power plants - Main control room - Alarm functions and presentation
October 1, 2015 - CEI

Scope and object This International Standard provides the functional requirements for the alarm systems in the main control room of nuclear power plants. It gives definitions of the terms used for alarm functions. It also establishes the human factors requirements and the design...

CEI EN 50130-5 - Alarm systems Part 5: Environmental test methods
July 1, 2012 - CEI

This European Standard specifies environmental test methods to be used for testing the system components of the following alarm systems, intended for use in and around buildings: - intruder alarm systems; - hold-up alarm systems; - social alarm systems; - CCTV systems,...

DS/EN 50130-5 - Alarm systems - Part 5: Environmental test methods
July 7, 2011 - DS

This European Standard specifies environmental test methods to be used for testing the system components of the following alarm systems, intended for use in and around buildings: - intruder alarm systems; - hold-up alarm systems; - social alarm systems; - CCTV systems,...

NG TS 3.07.24 - Technical Specifications (NGTS) - Alarm and Event Logging Legends
January 1, 1995 - NG

This Specification defines, for each substation alarm, the alarm legend and the preferred Alarm Data Rationalisation (ADR) group when the alarm is displayed on the following NGC devices:- (a) Local Control Point (LCP) Alarm Sub-System. (b) Substation Control Point...

IEC 62241 - Nuclear power plants Main control room Alarm functions and presentation
November 1, 2004 - IEC

Scope and object This International Standard provides the functional requirements for the alarm systems in the main control room of nuclear power plants. It gives definitions of the terms used for alarm functions. It also establishes the human factors requirements and the design...

ISA 18.2 - Management of Alarm Systems for the Process Industries
March 17, 2016 - ISA

General applicability This standard specifies general principles and processes for the lifecycle management of alarm systems based on programmable electronic controller and computer -based human-machine interface (HMI) technology for facilities in the process industries. It covers all...

UL 497C - Protectors for Coaxial Communications Circuits
August 3, 2001 - ULSE

00497c-000000-000000 1 Scope 1.1 These requirements cover protectors for use on coaxial cable circuits to be used in accordance with the applicable requirements of the National Electrical Code, NFPA 70. 1.2 As covered by these requirements, a coaxial cable circuit protector consists of single or...

ISO 7240-3 - Fire detection and alarm systems — Part 3: Audible alarm devices
March 1, 2020 - ISO

This document specifies the requirements, test methods and performance criteria for audible alarm devices intended to signal an audible warning, with or without voice messages between a fire detection and fire alarm system and the occupants of a building. This document...

IETF RFC 3878 - Alarm Reporting Control Management Information Base (MIB)
September 1, 2004 - IETF

This memo defines a portion of the Management Information Base (MIB) for use with network management protocols in TCP/IP-based internets. In particular, it defines objects for controlling the reporting of alarm conditions.

CEI CLC/TS 50398 - Alarm systems - Combined and integrated alarm systems - General requirements
October 1, 2013 - CEI

This Technical Specification specifies the requirements for alarm systems combined and integrated with other systems which may or may not be alarm systems. This Technical Specification defines requirements, related to integration, in order to complement the individual alarm...

IEC 62599-1 - Alarm systems – Part 1: Environmental test methods
May 1, 2010 - IEC

This part of IEC 62599 specifies environmental test methods to be used for testing the system components of the following alarm systems, intended for use in and around buildings: a) access control systems, for security applications; b) alarm transmission systems1; c) CCTV systems, for...

CEI CLC/TS 50134-9 - Alarm systems - Social alarm systems Part 9: IP Communications Protocol
April 1, 2019 - CEI

This Technical Specification specifies a protocol for point-to-point transmission of alarms, faults, control signals and communications monitoring, between a Local Unit and Controller and an Alarm Receiving Centre using the Internet protocol (IP). The protocol is intended for use over...

ANSI N13.27 - Performance Requirements for Pocket-Sized Alarm Dosimeters and Alarm Ratemeters
January 1, 1981 - HPS

This standard establishes performance requirements for pocket-sized chirpers, alarm dosimeters, and alarm ratemeters. Included within the scope of this standard are pocket-sized chirpers, pocket-sized dosimeters that provide an alarm at a preset integrated dose, and...

DS/CLC/TS 50134-9 - Alarm systems – Social alarm systems – Part 9: IP Communications Protocol
September 18, 2018 - DS

This Technical Specification specifies a protocol for point-to-point transmission of alarms, faults, control signals and communications monitoring, between a Local Unit and Controller and an Alarm Receiving Centre using the Internet protocol (IP). The protocol is intended for use over...

J994_202306 - Alarm - Backup - Electric Laboratory Performance Testing
June 27, 2023 - SAE International

The scope of this SAE Standard is the definition of the functional, environmental, and life cycle test requirements for electrically operated backup alarm devices primarily intended for use on off-road, self-propelled work machines as defined by SAE J1116 (limited to categories of (1)...

UL 38 - Manual Signaling Boxes for Fire Alarm Systems
July 3, 2008 - ULSE

000380-000000-000000 1 Scope 1.1 These requirements cover manual signaling boxes for fire alarm systems intended for permanent installation and used in ordinary locations in accordance with the National Electrical Code, NFPA 70, and the National Fire Alarm Code, NFPA 72....

EEMUA PUB NO 191 - Alarm Systems - A Guide to Design, Management and Procurement
September 1, 2013 - EEMUA

This Guide is primarily concerned with alarm systems provided for people operating industrial processes. These include alarm systems in industries such as chemical manufacture, power generation, oil and gas extraction and refining and others. The Guide has been compiled from the...