NR/L3/TRK/055/U20
Work Instructions for Ultrasonic Rail Testing: Ultrasonic Testing Procedure for Bolted IsolierstoB IVB 30° Scarf Joints
| Organization: | NR |
| Publication Date: | 3 September 2016 |
| Status: | active |
| Page Count: | 12 |
scope:
This document is to be used as a supplement to NR/L3/TRK/055 - U1 and specifies the ultrasonic techniques needed to test a bolted IsolierstoB IVB 30° Scarf Joint.
This procedure is capable of detecting the following defect types:-
- Horizontal defects
- Star cracks from bolt holes
Purpose
This procedure defines how to inspect a bolted IsolierstoB IVB 30° scarf joint for rail flaws using NR approved ultrasonic equipment to prevent broken rails.