scope:

This standard serves as a reference for the selection, design, installation, operation and maintenance of single-phase dynamic liquid mass measurement systems that operate in the 350 to 688 kg/m3 (0.350 to 0.689 relative density at 60°F) density range. The mass measurement systems within the scope of this document include inferred mass measurement, where volume at flowing conditions is combined with density at similar conditions to result in measured mass, as well as Coriolis mass measurement.

Liquids with density below 350 and above 688 kg/m3 (below 0.350 and above 0.689 relative density at 60°F) and cryogenic fluids (colder than approximately -50°F) are excluded from the scope of this document, but the principles described herein may apply to such streams.

NGL product should be analyzed to determine the mixture composition. These data should be considered in making a determination of the measurement methods and equipment to be used. It is especially important to use mass measurement whenever the range of molecular sizes is great, such as in high ethane content (more than 2 to 5% ethane) raw make. It is less critical when molecular sizes are similar, such as in the case of mixed butanes.

Sampling equipment and techniques are covered including standards for analytical methods used to determine the composition of the sampled product. Equations of state and correlations used to calculate the density of the product are discussed. The standard used to convert mass to equivalent liquid volumes of components is also discussed.

Equipment exists which uses diverse principles for measuring volume, sampling the product, and determining the composition and density of the product. This standard does not advocate the preferential use of any particular type of equipment. It is not the intention of this standard to restrict future development or improvement of equipment. The contracting parties to any agreement should mutually agree on the equipment to be used.

Document History

February 1, 2018
Manual of Petroleum Measurement Standards Chapter 14—Natural Gas Fluids Measurement Section 7—Mass Measurement of Natural Gas Liquids and Other Hydrocarbons
This standard describes the criteria for the equipment selection, design, installation, calculation processes, operation, and maintenance of single-phase dynamic liquid mass measurement systems that...
February 1, 2018
Manual of Petroleum Measurement Standards Chapter 14 - Natural Gas Fluids Measurement Section 7 - Mass Measurement of Natural Gas Liquids and Other Hydrocarbons
This standard describes the criteria for the equipment selection, design, installation, calculation processes, operation, and maintenance of single-phase dynamic liquid mass measurement systems that...
April 1, 2012
Manual of Petroleum Measurement Standards Chapter 14.7 - Mass Measurement of Natural Gas Liquids
This standard serves as a reference for the selection, design, installation, operation and maintenance of single-phase dynamic liquid mass measurement systems that operate in the 351.7 kg/m3 to 687.8...
API MPMS 14.7
October 1, 2009
Mass Measurement of Natural Gas Liquids
This standard serves as a reference for the selection, design, installation, operation and maintenance of single-phase dynamic liquid mass measurement systems that operate in the 350 to 688 kg/m3...
January 1, 1995
Standard for Mass Measurement of Natural Gas Liquids
This publication serves as a reference for the selection, design, installation, operation, and maintenance of single phase liquid mass measurement systems which operate in the 300 to 700 kghn3 (0.3...
January 1, 1995
Manual of Petroleum Measurement Standards Chapter 14 - Natural Gas Fluids Measurement Section 7 - Mass Measurement of Natural Gas Liquids
1. SCOPE This publication serves as a reference for the selection, design, installation, operation, and maintenance of single phase liquid mass measurement systems which operate in the 300 to 700...
January 1, 1991
Manual of Petroleum Measurement Standards Chapter 14 - Natural Gas Fluids Measurement Section 7 - Mass Measurement of Natural Gas Liquids