UNLIMITED FREE
ACCESS
TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

DSF/EN ISO 5359/FprA1

Low-pressure hose assemblies for use with medical gases - Amendment 1 (ISO 5359:2008/FDAM 1:2011)

pending
Organization: DS
Status: pending
Page Count: 10
ICS Code (Anaesthetic, respiratory and reanimation equipment): 11.040.10
ICS Code (Hoses): 83.140.40
scope:

1.1 * This International Standard specifies requirements for low-pressure hose assemblies intended for use with the following medical gases: . oxygen; . nitrous oxide; . medical air; . helium; . carbon dioxide; . xenon; . specified mixtures of the gases listed above; . oxygen-enriched air; . air for driving surgical tools; . nitrogen for driving surgical tools; . vacuum. It is intended in particular to ensure gas-specificity and to prevent cross-connection between systems conveying different gases. These hose assemblies are intended for use at maximum operating pressures of less than 1 400 kPa. 1.2 This International Standard specifies the allocation of non-interchangeable screw-threaded (NIST) connectors, diameter-index safety system (DISS) connectors and sleeve indexed system (SIS) connectors to medical gases and specifies the dimensions of non-interchangeable screw-threaded (NIST) connectors. 1.3 This International Standard does not specify: . requirements for coaxial hoses used for the supply and disposal of air for driving surgical tools; . requirements for electrical conductivity. 1.4 This International Standard does not specify the intended uses of hose assemblies. NOTE Some examples of intended use specified in other International Standards are as follows: a) between a terminal unit and medical equipment (ISO 9170-1, IEC 60601-2-12[7], IEC 0601-2-13[8]); b) between the fixed pipeline system and a terminal unit of that system (ISO 7396-1[10], ISO 61197[13]); c) between a terminal unit and a second terminal unit (ISO 7396-1); d) between an emergency supply and an emergency and maintenance inlet point of a pipeline system (ISO 10524-1[12], ISO 7396-1); e) between an emergency supply and medical equipment (ISO 10524-1, ISO 10524-3[16], IEC 60601-2-12, IEC 60601-2-13).

Document History

December 5, 2017
Anaesthetic and respiratory equipment – Low-pressure hose assemblies for use with medical gases – Amendment 1 (ISO 5359:2014/Amd 1:2017)
1.1 * This International Standard specifies requirements for low-pressure hose assemblies intended for use with the following medical gases — oxygen, — nitrous oxide, — medical air, — helium, —...
November 3, 2014
Anaesthetic and respiratory equipment - Low-pressure hose assemblies for use with medical gases
1.1 * This International Standard specifies requirements for low-pressure hose assemblies intended for use with the following medical gases ? oxygen, ? nitrous oxide, ? medical air, ? helium, ?...
February 2, 2012
Low-pressure hose assemblies for use with medical gases – Amendment 1
1.1 * This International Standard specifies requirements for low-pressure hose assemblies intended for use with the following medical gases: – oxygen; – nitrous oxide; – medical air; – helium; –...
July 7, 2008
Low-pressure hose assemblies for use with medical gases
1.1 * This International Standard specifies requirements for low-pressure hose assemblies intended for use with the following medical gases: – oxygen; – nitrous oxide; – medical air; – helium; –...
March 6, 2006
Low-pressure hose assemblies for use with medical gases
A description is not available for this item.
Anaesthetic and respiratory equipment – Low-pressure hose assemblies for use with medical gases – Amendment 1 (ISO 5359:2014/FDAmd 1:2017)
1.1 * This International Standard specifies requirements for low-pressure hose assemblies intended for use with the following medical gases — oxygen, — nitrous oxide, — medical air, — helium, —...
Anaesthetic and respiratory equipment - Low-pressure hose assemblies for use with medical gases (ISO 5359:2014/DAM 1:2015)
1.1 * This International Standard specifies requirements for low-pressure hose assemblies intended for use with the following medical gases — oxygen, — nitrous oxide, — medical air, — helium, —...
DSF/EN ISO 5359/FprA1
Low-pressure hose assemblies for use with medical gases - Amendment 1 (ISO 5359:2008/FDAM 1:2011)
1.1 * This International Standard specifies requirements for low-pressure hose assemblies intended for use with the following medical gases: . oxygen; . nitrous oxide; . medical air; . helium; ....
Anaesthetic and respiratory equipment - Low-pressure hose assemblies for use with medical gases (ISO/DIS 5359:2012)
1.1 * This International Standard specifies requirements for low-pressure hose assemblies intended for use with the following medical gases ? oxygen, ? nitrous oxide, ? medical air, ? helium, ?...
Advertisement