CSA/AM - ANSI Z21.13-2017/CSA 4.9-22

Gas-fired low pressure steam and hot water boilers

active, Most Current
Organization: CSA/AM
Publication Date: 1 August 2022
Status: active
Page Count: 231
ICS Code (Gas fuel burners): 27.060.20
scope:

This Standard applies to newly produced gas-fired low-pressure steam and hot water boilers with gas inlet pressure ratings not exceeding 0.5 psi (3.5 kPa) and having input ratings of less than 12 500 000 Btu/h (3 663 389 W) (see Clause 3), hereinafter referred to as boilers,* constructed entirely of new unused parts and materials,

a) for operation at or below the following pressures and temperatures:

i) steam heating boilers: 15 psi (103.42 kPa) steam pressure;

ii) hot water heating boilers:

1) 160 psi (1.10 MPa) water pressure; and

2) 250 °F (121 °C) water temperature;

iii) hot water supply boilers:

1) 160 psi (1.10 MPa) water pressure; and

2) 250 °F (121 °C) water temperature;

b) for use with

i) natural gas;

ii) propane gas;

iii) LP gas-air mixtures; and

c) for recreational vehicle installation for use with

i) propane gases only; and

ii) natural gas and propane gases when provision is made for the simple conversion from one gas to the other.

The construction of boilers is covered under Clause 4and the performance of boilers is covered under Clause 5.

* See Clause 7.2for boilers covered in Canada that exceed the above limits in gas inlet pressure and/or input ratings.

This Standard applies to indoor boilers, of other than the direct vent type that are categorized according to vent pressure and temperature as either Category I, Category II, Category III, or Category IV (see Clause 3), and to outdoor type boilers.

This Standard also applies to direct vent boilers (see Clause 3). A direct vent boiler anticipated by this Standard is essentially a balanced flue appliance with the air intake and vent outlet in proximity. Other designs are subjected to such additional tests as believed necessary at the discretion of the certification body.

If a value for measurement as given in this Standard is followed by an equivalent value in other units, the first stated value is the specification.

The values given in US customary units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

Note: IEEE/ASTM SI 10 or ISO 80000-1 can be used as a guide when converting imperial units to metric units.

All references to pressure throughout this Standard are considered gauge pressure, unless otherwise specified.

Clause 7contains clauses unique to, and required by, Canada.

In this Standard, "shall" is used to express a requirement, i.e., a provision that the user shall satisfy in order to comply with the Standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Document History

ANSI Z21.13-2017/CSA 4.9-22
August 1, 2022
Gas-fired low pressure steam and hot water boilers
This Standard applies to newly produced gas-fired low-pressure steam and hot water boilers with gas inlet pressure ratings not exceeding 0.5 psi (3.5 kPa) and having input ratings of less than 12 500...
January 1, 2017
Gas-fired low pressure steam and hot water boilers
A description is not available for this item.
January 1, 2017
Gas-fired low pressure steam and hot water boilers
A description is not available for this item.
January 1, 2014
Gas-fired low pressure steam and hot water boilers
This Standard applies to newly produced gas-fired low-pressure steam and hot water boilers with gas inlet pressure ratings not exceeding 0.5 psi (3.5 kPa) and having input ratings of less than...
January 1, 2014
Gas-fired low pressure steam and hot water boilers
This Standard applies to newly produced gas-fired low-pressure steam and hot water boilers with gas inlet pressure ratings not exceeding 0.5 psi (3.5 kPa) and having input ratings of less than...
July 1, 2013
Gas-Fired Low Pressure Steam And Hot Water Boilers
This standard applies to newly produced gas-fired low-pressure steam and hot water boilers with gas inlet pressure ratings not exceeding ½ psi (3.5 kPa) and having input ratings of less than...
July 1, 2012
Standard for Gas-fired low pressure steam and hot water boilers
This standard applies to newly produced gas-fired low-pressure steam and hot water boilers with gas inlet pressure ratings not exceeding 0.5 psi (3.5 kPa) and having input ratings of less than...
February 1, 2010
Gas-Fired Low Pressure Steam And Hot Water Boilers
Preface The standards set forth herein apply to the third edition of the Standard for Gas-Fired Low Pressure Steam And Hot Water Boilers, ANSI Z21.13-2010 CSA 4.9-2010 and supersede corresponding...
January 1, 2010
Gas-Fired Low Pressure Steam And Hot Water Boilers
This standard applies to newly produced gas-fired low-pressure steam and hot water boilers with gas inlet pressure ratings not exceeding ½ psi (3.5 kPa) and having input ratings of less than...
November 1, 2007
Gas-Fired Low Pressure Steam And Hot Water Boilers
A description is not available for this item.
April 1, 2005
Gas-Fired Low Pressure Steam And Hot Water Boilers
Preface The standards set forth herein apply to the fourth edition of the Standard for Gas-Fired Low Pressure Stream and Hot Water Boilers, ANSI Z21.13-2004 • CSA 4.9-2004 and supersede...
August 1, 2004
Gas-Fired Low Pressure Steam And Hot Water Boilers
This standard applies to newly produced gas-fired low-pressure steam and hot water boilers with gas inlet pressure ratings not exceeding ½ psi (3.5 kPa) and having input ratings of less than...
January 1, 2000
Gas-Fired Low Pressure Steam and Hot Water Boilers
PREFACE The standards set forth herein apply to the first edition of the Standard for Gas-Fired Low Pressure Steam and Hot Water Boilers, ANSI Z21.13-2000 • CSA 4.9-2000, and supersede corresponding...
Gas-Fired Low Pressure Steam and Hot Water Boilers
This standard applies to newly produced gas-fired low-pressure steam and hot water boilers with gas inlet pressures not exceeding 1/2 psi (3.45 kPa) and having input ratings of less than 12,50,000...
January 1, 2000
Gas-Fired Low Pressure Steam and Hot Water Boilers
PREFACE This publication represents a basic standard for safe operation, Substantial and durable construction, and acceptable performance of gas-fired low pressure steam and hot water boilers. It is...
Gas-Fired Low Pressure Steam and Hot Water Boilers
PREFACE The standards set forth herein apply to the first edition of the Standard for Gas-Fired Low Pressure Steam and Hot Water Boilers, ANSI Z21.13-2000 • CSA 4.9-2000, and supersede corresponding...
January 1, 1994
Gas-Fired Low-Pressure Steam and Hot Water Boilers
PREFACE The standards set forth herein apply to the twenty-second edition of the Standard for Gas-Fired Low-Pressure Steam and Hot Water Boilers, ANSI 221.13-1991, and Addenda thereto, Z21.13a-1993,...
January 1, 1993
Gas-Fired Low-Pressure Steam and Hot Water Boilers
PREFACE The standards set forth herein apply to the twenty-second edition of the Standard for Gas-Fired Low-Pressure Steam and Hot Water Boilers, ANSI Z21.13- 1991, and supersede corresponding...
January 1, 1991
Gas-Fired Low-Pressure Steam and Hot Water Boilers
This standard applies to newly produced gas-fired low-pressure steam and hot water boilers with gas inlet pressure ratings not exceeding 1/2 psi (3.5 kPa) and having input ratings of less than...
January 1, 1987
GAS-FIRED LOW-PRESSURE STEAM AND HOT WATER BOILERS TWENTY-FIRST EDITION; ADDENDA Z21.13A - 1989, ADDENDA Z21.13B - 1991
PREFACE This publication represents a basic standard for safe operation, substantial and durable construction, and acceptable performance of gas-fired low-pressure steam and hot water boilers. It is...
January 1, 1982
Gas-fired low pressure steam and hot water boilers
GENERAL CONSTRUCTION Materials, including insulation , used in the construction of a boiler shall be suitable for the application and the temperatures to which exposed in service and shall not show...
January 1, 1982
GAS-FIRED LOW-PRESSURE STEAM AND HOT WATER BOILERS; ADDENDA Z21.13A - 1983
PREFACE This publication represents a basic standard for safe operation, substantial and durable construction, and acceptable performance of gas-fired low-pressure steam and hot water boilers. It is...