CENELEC - EN 60269-4

Low-voltage fuses - Part 4: Supplementary requirements for fuse-links for the protection of semiconductor devices

inactive
Organization: CENELEC
Publication Date: 1 November 2009
Status: inactive
Page Count: 58
ICS Code (Fuses and other overcurrent protection devices): 29.120.50
scope:

Scope and object

These supplementary requirements apply to fuse-links for application in equipment containing semiconductor devices for circuits of nominal voltages up to 1 000 V a.c. or 1 500 V d.c. and also, in so far as they are applicable, for circuits of higher nominal voltages.

NOTE 1 Such fuse-Iinks are commonly referred to as "semiconductor fuse-links".

NOTE 2 In most cases, a part of the associated equipment serves the purpose of a fuse-base. Owing to the great variety of equipment, no general rules can be given; the suitability of the associated equipment to serve as a fusebase should be subject to agreement between the manufacturer and the user. However, if separate fuse-bases or fuse-holders are used, they should comply with the appropriate requirements of IEC 60269-1.

NOTE 3 IEC 60269-6 (Low-voltage fuses - Part 6: Supplementary requirements for fuse-links for the protection of solar photovoltaic energy systems) is dedicated to the protection of solar photovoltaic energy systems.

The object of these supplementary requirements is to establish the characteristics of semiconductor fuse-links in such a way that they can be replaced by other fuse-links having the same characteristics, provided that their dimensions are identical. For this purpose, this standard refers in particular to

a) the following characteristics of fuses:

1) their rated values;

2) their temperature rises in normal service;

3) their power dissipation;

4) their time-current characteristics;

5) their breaking capacity;

6) their cut-off current characteristics and their I2t characteristics;

7) their arc voltage characteristics;

b) type tests for verification of the characteristics of fuses;

c) the markings on fuses;

d) availability and presentation of technical data (see Annex B).

Document History

November 1, 2009
Low-voltage fuses - Part 4: Supplementary requirements for fuse-links for the protection of semiconductor devices
Scope and object These supplementary requirements apply to fuse-links for application in equipment containing semiconductor devices for circuits of nominal voltages up to 1 000 V a.c. or 1 500 V...
EN 60269-4
November 1, 2009
Low-voltage fuses - Part 4: Supplementary requirements for fuse-links for the protection of semiconductor devices
Scope and object These supplementary requirements apply to fuse-links for application in equipment containing semiconductor devices for circuits of nominal voltages up to 1 000 V a.c. or 1 500 V...
November 1, 2009
Low-voltage fuses - Part 4: Supplementary requirements for fuse-links for the protection of semiconductor devices
A description is not available for this item.
May 1, 2007
Low-voltage fuses - Part 4: Supplementary requirements for fuse-links for the protection of semiconductor devices
A description is not available for this item.
August 1, 1996
Low-voltage fuses Part 4: Supplementary requirements for fuse-links for the protection of semiconductor devices
A description is not available for this item.

References

Advertisement