IEEE - ANSI C37.41

Design Tests for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories

inactive
Buy Now
Organization: IEEE
Publication Date: 1 January 1981
Status: inactive
Page Count: 38
scope:

This standard applied to tests for high-voltage fuses (above 600 V), distribution enclosed single-pole air switches, fuse disconnecting switches, and accessories (for alternating-current distribution systems) as follows:

(1) Enclosed, open, and open-link types of distribution cutouts and fuses

(2) Distribution current limiting fuses

(3) Distribution oil cutouts

(4) Distribution enclosed single-pole air switches

(6) Power fuses, including current-limiting types

(6) Outdoor and indoor fuse disconnecting switches

(7) Fuse supports, fuse mountings, fuse hooks, fuse tongs, and fuse links, all of the type used exclusively with products listed in (1) through (6), above

(8) Removable switch blades for products listed in (1) through (3), above

Document History

December 6, 2017
Design Tests for High-Voltage (>1000 V) Fuses and Accessories
A description is not available for this item.
September 22, 2016
Design Tests for High-Voltage (>1000 V) Fuses and Accessories
This standard specifies design test requirements for high-voltage (above 1000 V) fuses and accessories for use on ac electrical distribution systems. Devices with rated maximum voltages to 170 kV are...
May 22, 2009
Errata to IEEE Standard Design Tests for High-Voltage (>1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with These Devices
This standard specifies design test requirements for high-voltage (above 1000 V) fuses, distribution enclosed single-pole air switches, fuse disconnecting switches, and accessories for use on...
May 22, 2009
Errata to IEEE Standard Design Tests for High-Voltage (>1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with These Devices
This standard applies to tests for high voltage fuses above 600 volts), secondary fuses, distribution enclosed single-people air switches, and accessories, as follows: (1) Enclosed, open, and...
November 10, 2008
Standard Design Tests for High-Voltage (>1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with These Devices
This standard specifies design test requirements for high-voltage (above 1000 V) fuses, distribution enclosed single-pole air switches, fuse disconnecting switches, and accessories for use on...
January 30, 2000
Standard Design Test for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
This standard specifies design test requirements for high-voltage (above 1000 V) fuses, distribution enclosed single-pole air switches, fuse disconnecting switches, and accessories for use on...
August 9, 1996
Standard Design Tests for External Fuses for Shunt Capacitors
A description is not available for this item.
September 22, 1994
Standard Design for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
A description is not available for this item.
September 26, 1991
TEST STANDARD FOR EXPULSION FUSES IN ENCLOSURES SUPPLEMENT TO IEEE STANDARD DESIGN TESTS FOR HIGH-VOLTAGE FUSES, DISTRIBUTION ENCLOSED SINGLE-POLE AIR SWITCHES, FUSE DISCONNECTING SWITCHES, AND ACCESSORIES (SUPPLEMENT TO IEEE C37.41-1988)
A description is not available for this item.
January 1, 1991
Test Standard for Expulsion Fuses in Enclosures
A description is not available for this item.
March 10, 1988
STANDARD DESIGN TESTS FOR HIGH-VOLTAGE FUSES, DISTRIBUTION ENCLOSED SINGLE-POLE AIR SWITCHES, FUSE DISCONNECTING SWITCHES, AND ACCESSORIES
A description is not available for this item.
December 14, 1981
Design Tests for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
A description is not available for this item.
ANSI C37.41
January 1, 1981
Design Tests for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories
This standard applied to tests for high-voltage fuses (above 600 V), distribution enclosed single-pole air switches, fuse disconnecting switches, and accessories (for alternating-current distribution...