CSA/AM - ANSI Z21.50-1982

VENTED DECORATIVE GAS APPLIANCES; ADDENDA Z21.50A - 1982, ADDENDA Z21.50B - 1985

inactive
Organization: CSA/AM
Publication Date: 1 January 1982
Status: inactive
Page Count: 77
scope:

This standard applies to automatically operating gas-fired central furnaces (see Part XI, Definitions), hereinafter referred to as furnaces, for installation in residential, commercial, and industrial structures including furnaces for Direct Vent, Recreational Vehicle, Outdoor, and Manufactured (Mobile) Homes.

These furnaces may include a cooling unit. All units shall be constructed entirely of new, unused parts and materials.

In Canada, this standard applies to gas-fired central furnaces having inputs up to and including 400,000 Btu per hour (ll7 228 W).

This standard applies to Category I, Category II, Category III and Category IV Central Furnaces (see Part XI, Definitions).

This standard applies to furnaces of the types defined in Part XI, Definitions, which are designed to supply heated air through ducts to spaces remote from or adjacent to the furnace location. Location and use of such furnaces with respect to the spaces being heated necessitates automatic operation of the appliance.

This standard covers the thermal efficiency (2.38) and related markings of only those furnaces whose efficiencies are not regulated in the U.S.A. by the Energy Policy Act and Conservation Act of 1975 and the National Energy Conservation Policy of 1978* or not covered in Canada by Exhibit M (M1.1), when connected to single phase electrical supply.

A furnace of a type not specifically defined in this standard may be subjected to such examination and tests as deemed necessary by the testing agency to determine compliance with the intent of this standard.

This standard also applies to a furnace which is factory equipped with both a draft hood and an automatic vent damper device (see Part XI, Definitions), hereinafter referred to as vent damper device.

Unless otherwise indicated on its rating plate, a furnace shall be for installation indoors in accordance with its markings and the manufacturer's installation instructions. When specified additional or alternate provisions are met, a furnace may be for manufactured (mobile) home installation or for use outdoors.

A furnace for manufactured (mobile) home installation shall be designed so when installed in accordance with the manufacturer's installation instructions supplied with the furnace, it shall provide complete separation of its combustion system from the living space of the manufactured (mobile) home. The complete separation of the furnace combustion system from the living space of the manufactured (mobile) home is accomplished by the furnace being designed and installed so (1) all air supplied for combustion, (2) the combustion system of the furnace and (3) all products of combustion are completely isolated from the living space. Doors, panels and any other access openings of the structure serving an enclosure required for such isolation are to communicate only to the outdoors. A furnace which by its inherent design provides such complete separation is referred to as a direct vent central furnace (see Part XI, Definitions).

A furnace shall be for use with one or more of the gases specified in 2.1.1 A furnace for manufactured (mobile) home installation shall be convertible for use with natural gas and liquefied petroleum gases.

Special construction provisions applicable to Category II, III, or Iv furnaces are outlined under 1.1.10, 1.2.23, 1.2.24, 1.14, 1.15.15 through 1.15.17, 1.23.1, -c13, -c16, -d4, and -d5, 1.24.2-i and -j, 1.25.2-d and 1.25.9-f.

A furnace for indoor installation designed to vent the flue gases horizontally through an outside wall shall be specified as Category III or IV, except Category I furnaces utilizing a listed mechanical venter applied externally to the venting system.

Special construction provisions applicable to a furnace for manufactured (mobile) home installation are outlined under 1.1.8, 1.1.9, 1.1.10, 1.2.22, 1.6.5, 1.11.17, 1.23.1-c4, 1.23.5, 1.25.2-f, 1.25.9-b and 1.25.9-h and Part III.

Special construction provisions

Document History

January 1, 2019
Vented decorative gas appliances
This Standard applies to newly produced vented decorative gas appliances (see Clause 3, Definitions), hereinafter referred to as appliances, constructed entirely of new, unused parts and materials...
January 1, 2016
Vented decorative gas appliances
A description is not available for this item.
January 1, 2014
Vented gas fireplaces
This Standard applies to newly produced vented gas fireplaces (see Clause 3, Definitions), hereinafter referred to as appliances, constructed entirely of new, unused parts and materials and having...
January 1, 2014
Vented gas fireplaces
This Standard applies to newly produced vented gas fireplaces (see Clause 3, Definitions), hereinafter referred to as appliances, constructed entirely of new, unused parts and materials and having...
December 1, 2012
Vented gas fireplaces
This standard applies to newly produced vented gas fireplaces (see Part IV, Definitions), hereinafter referred to as appliances, constructed entirely of new, unused parts and materials, and having...
February 1, 2009
Vented Gas Fireplaces
Preface: The standards set forth herein apply to the fifth edition of the Standard for Vented Gas Fireplaces ANSI Z21.50-2007 • CSA 2.22-2007 and Addenda ANSI Z21.50a-2008 • CSA 2.22a-2008 and...
April 1, 2008
Vented Gas Fireplaces
Preface: The standards set forth herein apply to the fifth edition of the Standard for Vented Gas Fireplaces, Z21.50-2007 • CSA 2.22-2007 and supersede corresponding standards therein. Following...
March 1, 2007
Vented Gas Fireplaces
This standard applies to newly produced vented gas fireplaces, hereinafter referred to as appliances, constructed entirely of new, unused parts and materials, and having input ratings up to and...
January 1, 2005
Vented Gas Fireplaces
Preface The standards set forth herein apply to the fourth edition of the Standard for Vented Gas Fireplaces, ANSI 221 SO-2003 CSA 2.22-2003, ANSI 221 Soa-2003 CSA 2.22a-2003 and supersede...
December 1, 2003
Vented Gas Fireplaces
A description is not available for this item.
December 1, 2003
Vented Gas Fireplaces
PREFACE This publication represents a basic standard for safe operation, substantial and durable construction, and acceptable performance of vented gas fireplaces. It is the result of years of...
Vented Gas Fireplaces
This standard applies to newly produced vented gas fireplaces (See Part IV, Definitions), hereinafter referred to as appliances, constructed entirely of new, unused parts and materials: a. For use...
January 1, 2000
Vented Gas Fireplaces
PREFACE The standards set forth herein appiy to the third edition of the Standard for Vented Gas Fireplaces, ANSI Z21.50-2000 CSA 2.22-2000, and Addenda Z21.50a-2001 CSA 2.22a-2001, and supersede...
January 1, 2000
Addenda to Z21.50-1998 Vented Gas Fireplaces
The standards set forth herein apply to the second edition of the Standard for Vented Gas Fireplaces, ANSI 221 SO-1 998 CSA 2.22-M98, and Addenda Z21.50a-1999 . CSA 2.22a-M99, and supersede...
January 1, 2000
Vented Gas Fireplaces
PREFACE This publication represents a basic standard for safe operation, substantial and durable construction, and acceptable performance of vented gas fireplaces. It is the result of years of...
June 1, 1999
Vented Gas Fireplaces
PREFACE The standards set forth herein apply to the second edition of the Standard for Vented Gas Fireplaces, ANSI Z21.50-1998 CSA 2.22-M98, and supersede corresponding standards therein. Following...
November 1, 1998
Vented Gas Fireplaces
PREFACE This publication represents a basic standard for safe operation, substantial and durable construction, and acceptable performance of vented gas fireplaces. It is the result of years of...
January 1, 1996
Vented Gas Fireplaces
PREFACE This publication represents a basic standard for safe operation, substantial and durable construction, and acceptable performance of decorative gas appliances for installation in vented gas...
Vented Gas Fireplaces First Edition (CGA 2.22-M96)
This standard applies to newly produced vented gas fireplaces (See Part IV, Definitions), hereinafter referred to as appliances, constructed entirely of new, unused parts and materials, and having...
January 1, 1989
VENTED DECORATIVE GAS APPLIANCES EIGHTH EDITION; ADDENDA Z21.50A - 1990, ADDENDA Z21.50B - 1990
PREFACE The standards set forth herein apply to the eighth edition of the Standard for Vented Decorative Gas Appliances, ANSI Z21.50-1989, and Addenda thereto, ANSI Z21.50a-1990, and supersede...
January 1, 1986
VENTED DECORATIVE GAS APPLIANCES SEVENTH EDITION; ADDENDA Z21.50A - 1987, ADDENDA Z21.50B - 1988
A description is not available for this item.
ANSI Z21.50-1982
January 1, 1982
VENTED DECORATIVE GAS APPLIANCES; ADDENDA Z21.50A - 1982, ADDENDA Z21.50B - 1985
This standard applies to automatically operating gas-fired central furnaces (see Part XI, Definitions), hereinafter referred to as furnaces, for installation in residential, commercial, and...