1.1 This specification covers the manufacture and purchase requirements of products used for the assembly and construction of circular vertical precast reinforced concrete manholes and structures used in sewer, drainage, and water works. 1.2 Part I, Sections 1 - 11, of this specification presents...
This specification covers installation procedures for lock-strip gaskets and for infill glazing materials in lock-strip gasket glazing applications used in building walls. The prime performance considerations are weathertightness against air and water infiltration, and structural integrity under...
5.1 Ladder designs can vary greatly in, for example: number and size of steps, geometry, and materials, and for a variety of industries. Fig. 2 shows examples of various ladders. 5.2.1 Example-A test requestor instructs that a lower-body exoskeleton is to be worn by five able-bodied...
1.1 This specification establishes requirements for devices intended to address the risk of injury and death associated with accidental falls through open windows by children five years old and younger. 1.2 This specification is not intended to meet the unique requirements of Americans With...
5.1 General-This procedure is used for evaluation of the structural integrity of atmospheric storage tanks. The AE method can detect flaws which are in locations that are stressed during pressurization. Such locations include the tank wall, welds attaching pads to the tank, nozzle attachments, and...
4.1 With the rapid growth of the use of photovoltaic systems in buildings, roof mounted arrays continue to be one of the most prevalent forms of installations. These roof mounted arrays typically feature penetrations into the roof system, which can result in water leakage issues if not properly...
1.1 This consumer safety performance specification provides safety and performance requirements for various types of public use play equipment such as, but not limited to, composite play structures, climbing structures, to-fro swings, spring rocking equipment, and slides. It is intended to apply to...
1.1 This standard covers the specification and qualification testing of insulating ladders used for performing live line work by electrical workers. 1.2 These insulating ladders are used to provide access, generally on overhead power line structures and to facilitate live line work...
1.1 This safety specification covers the components, the assembly, and the use of consumer trampolines. 1.2 This specification is delimited in its application to trampolines of (1) a minimum bed size of 3300 in.2 (21 300 cm2), (2) a minimum height of 20 in. (51 cm), (3) intended for the purpose of...
This specification establishes the requirements for treestands, climbing sticks, and tripod/tower stands that are used for hunting, photographing, or general observation. It covers ladder treestands; non-climbing, fixed position or hang-on treestands; climbing sticks (continuous); climbing...
The purpose of this report is to outline types of in-service heat damage that have been observed in high strength steel landing gear components, with an emphasis on a particular type that is referred to as "Ladder Cracking" which can develop in landing gear shock struts. The report discusses...
1.1 This specification covers the chemical and mechanical requirements of hexagon and square-head zinc-coated steel bolts and atmospheric corrosion-resistant bolts, in nominal thread diameters of 1/2 , 5/8 , 3/4 , 7/8 and 1 in. for use in the construction of transmission towers, substations, and...
This specification establishes the recognized performance requirements and corresponding test procedures for portable and permanent emergency escape ladders for residential use. The ladder shall show evidence of good workmanship and meet the requirements specified for the following:...
1.1 This practice covers design, construction, and installation criteria for platforms in cargo tanks. 1.2 Where platforms are attached to ladders see Figs. 1-4. FIG. 1 Cargo Platform-Bulkhead FIG. 2 Cargo Platform Elevation FIG. 3 Cargo Platform-Girder FIG. 4 Cargo Platforms Showing Typical...
4.1 The objective of this practice is to provide ergonomic design criteria for maritime vessels and structures to ensure that maritime systems and equipment are designed in compliance with requirements for human performance, human workload, health and safety, survivability, and habitability. 4.2...
1.1 This test method covers the procedures for determining the capability of climbing and ladder treestands, climbing sticks (Sectional and Continuous), and tripods/towers to withstand repeated loading relative to the manufacturer's rated capacity. For actual specification requirements for...
This specification covers products used in the assembly and construction of circular reinforced corrugated steel manholes for sewer and water works. Requirements are specified for the manufacture and purchase of: steel sheet for manhole structure(s) pipe, steel sheet for coupling bands, rivets,...
4.1 The objective of this practice is to provide ergonomic design criteria for maritime vessels and structures to ensure that maritime systems and equipment are designed in compliance with requirements for human performance, human workload, health and safety, survivability, and habitability. 4.2...
4.1 A-UGVs navigate, dock, or perform other tasks, or combinations thereof, within for example manufacturing, warehouse, hospital, and other environments. Objects (defined in Terminology F3200 as anything in the environment that is not infrastructure) and obstacles (defined in Terminology F3200 as...
1.1 This specification covers the manufacture and purchase requirements of products used for the assembly and construction of circular vertical precast reinforced concrete manholes and structures used in sewer, drainage, and water works. 1.2 Part I, Sections 1 - 11, of this specification presents...
Narrow Your Results