DS/IEC/TS 60076-19 - Power transformers - Part 19: Rules for the determination of uncertainties in the measurement of losses in power transformers and reactors
June 10, 2013 - DS

This Technical Specification illustrates the procedures that should be applied to evaluate the uncertainty affecting the measurements of no-load and load losses during the routine tests on power transformers. Even if the attention is especially paid to the transformers,...

IEC/TS 60076-19 - Power transformers – Part 19: Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors
March 1, 2013 - IEC

This part of IEC 60076, which is a Technical Specification, illustrates the procedures that should be applied to evaluate the uncertainty affecting the measurements of no-load and load losses during the routine tests on power transformers. Even if the attention is especially...

DS/EN 60076-19 - Power transformers – Part 19: Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors
September 16, 2015 - DS

To illustrate the procedures that should be applied to evaluate the uncertainty affecting the measurements of no-load and load losses during the routine tests on power transformers.

CSA C802 - Maximum Losses for Distribution, Power, and Dry-Type Transformers
January 1, 1994 - CSA

This Standard specifies maximum losses for distribution, power, and dry-type transformers of types similar to or as described in CSA Standards CAN/CSA-C2, CAN/CSA-C9, CAN/CSA-C22.2 No. 47, CAN/CSA-C88, CAN/CSA-C227.3, C227.4, and C301.1. The losses specified are for...

Power Transformer Design Practices
March 19, 2021 - CRC

The book presents basic theories of transformer operation, design principles and methods used in power transformer designing work, and includes limitation criteria, effective utilization of material, and calculation examples to enhance readers' techniques of transformer...

DSF/CLC/PRTR 50462 - Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors
August 5, 2008 - DS

This Technical Report illustrates the procedures and criteria to be applied to evaluate the uncertainty affecting the measurements of no load and load losses during the routine tests on power transformers. Even if the attention is especially paid to the transformers, the...

DS/CLC/TR 50462 - Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors
August 5, 2008 - DS

This Technical Report illustrates the procedures and criteria to be applied to evaluate the uncertainty affecting the measurements of no load and load losses during the routine tests on power transformers. Even if the attention is especially paid to the transformers, the...

IEEE C57.120 - Guide for Loss Evaluation of Distribution and Power Transformers and Reactors
February 14, 2017 - IEEE

This guide covers the economic loss evaluation of liquid-filled distribution and power transformers, dry-type distribution and power transformers, and reactors. Purpose The purpose of this guide is to provide a method of establishing the dollar value of the...

IEEE C57.123 - Guide for Transformer Loss Measurement
November 7, 2019 - IEEE

This guide provides background information and general recommendations of instrumentation, circuitry, calibration, and measurement techniques of no-load losses (excluding auxiliary losses), excitation current, load losses of power, and distribution transformers....

MIL-T-48319 - TRANSFORMER
NPFC
A description is not available for this item.
Transformer Engineering: Design, Technology, and Diagnostics
September 6, 2012 - CRC

Transformer Engineering: Design, Technology, and Diagnostics, Second Edition helps you design better transformers, apply advanced numerical field computations more effectively, and tackle operational and maintenance issues. Building on the bestselling Transformer Engineering:...

ASTM A1009-18 - Standard Specification for Soft Magnetic MnZn Ferrite Core Materials for Transformer and Inductor Applications
October 1, 2018 - ASTM International

This specification deals with soft magnetic manganese zinc ferrite core materials for high frequency power transformer and filter inductor applications. Standard types of both power transformer and filter inductor material are defined. For power transformer...

ASTM A1009-05(2010) - Standard Specification for Soft Magnetic MnZn Ferrite Core Materials for High Frequency (10 kHz-1 MHz) Power Transformer and Filter Inductor Applications
November 1, 2010 - ASTM International

This specification deals with soft magnetic manganese zinc ferrite core materials for high frequency power transformer and filter inductor applications. Standard types of both power transformer and filter inductor material are defined. For power transformer...

ASTM A1009-05 - Standard Specification for Soft Magnetic MnZn Ferrite Core Materials for High Frequency (10 kHz-1 MHz) Power Transformer and Filter Inductor Applications
November 1, 2005 - ASTM International

This specification deals with soft magnetic manganese zinc ferrite core materials for high frequency power transformer and filter inductor applications. Standard types of both power transformer and filter inductor material are defined. For power transformer...

DSF/PREN 50708-2-4 - Power transformers – Additional European requirements – Part 2-4: Medium power transformer – Special tests
DS

This document describes the special test for Medium Power Transformers ≤ 3150kVA compliant with the EN 50708 2 series: - for corrugated tank liquid immersed transformers; - for the method of measurement of losses for one winding in Highest Voltage (HV) and 2 windings in...