loading
IPC/JEDEC-9704 - Printed Circuit Assembly Strain Gage Test Guideline
February 1, 2012 - IPC

This document is meant to be used as a methodology for strain gage placement and subsequent testing of Printed Circuit Assemblies (PCAs) using strain gages. The method describes specific guidelines for strain gage testing of PCAs during the printed board...

ISA 37.3 - Specifications and Tests for Strain Gage Pressure Transducers
January 1, 1982 - ISA

This Standard covers strain gage pressure transducers, but primarily those used in measurement systems. Included among the specific versions of strain gage pressure transducers to which this Standard is applicable are the following: Absolute Pressure Transducers...

ISA 37.5 - Specifications and Tests for Strain Gage Linear Accelerator Transducers
January 1, 1982 - ISA

This Standard covers uni-directional and bi-directional strain-gage linear acceleration transducers. Included among the specific types of strain-gage linear acceleration transducers for which this Standard is applicable, are the following: Bonded, unbonded, deposited...

ISA 37.8 - Specifications and Tests for Strain Gage Force Transducers
January 1, 1982 - ISA

This standard covers strain-gage force transducers, primarily those used in measurement systems. Included among the specific versions of strain-gage force transducers, to which this Standard is applicable, are the following: Tension Transducers Compression Transducers...

NAS942 - STRAIN GAGES, BONDED RESISTANCE
January 29, 2016 - AIA/NAS
A description is not available for this item.
ASTM E1237-93(2003) - Standard Guide for Installing Bonded Resistance Strain Gages
April 10, 1998 - ASTM International

1.1 This document provides guidelines for installing bonded resistance strain gages. It is not intended to be used for bulk or diffused semiconductor gages. This document pertains only to adhesively bonded strain gages. 1.2 This standard does not purport to...

ASTM E1237-93(1998) - Standard Guide for Installing Bonded Resistance Strain Gages
April 10, 1998 - ASTM International

1.1 This document provides guidelines for installing bonded resistance strain gages. It is not intended to be used for bulk or diffused semiconductor gages. This document pertains only to adhesively bonded strain gages. 1.2 This standard does not purport to...

ASTM E1561-93(2014) - Standard Practice for Analysis of Strain Gage Rosette Data
April 15, 2014 - ASTM International

1.1 The two primary uses of three-element strain gage rosettes are (a) to determine the directions and magnitudes of the principal surface strains and (b) to determine residual stresses. Residual stresses are treated in a separate ASTM standard, Test Method E837. This practice...

ASTM E1561-93(2009) - Standard Practice for Analysis of Strain Gage Rosette Data
September 1, 2009 - ASTM International

1.1 The two primary uses of three-element strain gage rosettes are (a) to determine the directions and magnitudes of the principal surface strains and (b) to determine residual stresses. Residual stresses are treated in a separate ASTM standard, Test Method E 837 . This...

ASTM E1561-93(2003) - Standard Practice for Analysis of Strain Gage Rosette Data
June 10, 2003 - ASTM International

1.1 The two primary uses of three-element strain gage rosettes are (a) to determine the directions and magnitudes of the principal surface strains and (b) to determine residual stresses. Residual stresses are treated in a separate ASTM standard, Test Method E837. This practice...

ASTM E1561-93(1998) - Standard Practice for Analysis of Strain Gage Rosette Data
April 10, 1998 - ASTM International

1.1 The two primary uses of three-element strain gage rosettes are (a) to determine the directions and magnitudes of the principal surface strains and (b) to determine residual stresses. Residual stresses are treated in a separate ASTM standard, Test Method E837. This practice...

ASTM E1237-20 - Standard Guide for Installing Bonded Resistance Strain Gages
August 15, 2020 - ASTM International

1.1 This guide provides guidelines for installing bonded resistance strain gages. It is not intended to be used for bulk or diffused semiconductor gages. This guide pertains only to adhesively bonded strain gages. 1.2 The values stated in SI units are to be...

ASTM E1237 - Standard Guide for Installing Bonded Resistance Strain Gages
August 15, 2020 - ASTM

This guide provides guidelines for installing bonded resistance strain gages. It is not intended to be used for bulk or diffused semiconductor gages. This guide pertains only to adhesively bonded strain gages. The values stated in SI units are to be regarded as...

ASTM E1561-20 - Standard Practice for Analysis of Strain Gage Rosette Data
September 1, 2020 - ASTM International

1.1 The two primary uses of three-element strain gage rosettes are (a) to determine the directions and magnitudes of the principal surface strains and (b) to determine residual stresses. Residual stresses are treated in a separate ASTM standard, Test Method E837. This practice...

ASTM E1237-93(2014) - Standard Guide for Installing Bonded Resistance Strain Gages
April 15, 2014 - ASTM International

1.1 This guide provides guidelines for installing bonded resistance strain gages. It is not intended to be used for bulk or diffused semiconductor gages. This document pertains only to adhesively bonded strain gages. 1.2 The values stated in inch-pound units are...

ASTM E1237-93(2009) - Standard Guide for Installing Bonded Resistance Strain Gages
April 1, 2009 - ASTM International

1.1 This guide provides guidelines for installing bonded resistance strain gages. It is not intended to be used for bulk or diffused semiconductor gages. This document pertains only to adhesively bonded strain gages. 1.2 The values stated in inch-pound units are...

ASTM E1561 - Standard Practice for Analysis of Strain Gage Rosette Data
September 1, 2020 - ASTM

The two primary uses of three-element strain gage rosettes are (a) to determine the directions and magnitudes of the principal surface strains and (b) to determine residual stresses. Residual stresses are treated in a separate ASTM standard, Test Method E837. This practice...

ASTM E251 - Standard Test Methods for Performance Characteristics of Metallic Bonded Resistance Strain Gages
June 1, 2020 - ASTM

The purpose of these test methods are to provide uniform test methods for the determination of strain gage performance characteristics. Suggested testing equipment designs are included. Strain gages are very sensitive devices with essentially infinite resolution. Their...

IPC/JEDEC-9704 CHINESE - Printed Wiring Board Strain Gage Test Guideline
February 1, 2012 - IPC
A description is not available for this item.
ASTM E1949-03(2009) - Standard Test Method for Ambient Temperature Fatigue Life of Metallic Bonded Resistance Strain Gages
April 1, 2009 - ASTM International

Strain gages are the most widely used devices for measuring strains and for evaluating stresses in structures. In many applications there are often cyclic loads which can cause strain gage failure. Performance parameters of strain gages are affected...