CEI - EN IEC 60601-2-43

Medical electrical equipment Part 2: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures

active, Most Current
Organization: CEI
Publication Date: 1 April 2023
Status: active
Page Count: 70
ICS Code (Radiographic films): 37.040.25
ICS Code (Radiographic equipment): 11.040.50
scope:

This document applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of both FIXED and MOBILE X-RAY EQUIPMENT declared by the MANUFACTURER to be suitable for RADIOSCOPICALLY GUIDED INTERVENTIONAL PROCEDURES, hereafter referred to as INTERVENTIONAL X-RAY EQUIPMENT. Its scope excludes, in particular:

- equipment for RADIOTHERAPY;

- equipment for COMPUTED TOMOGRAPHY;

- ACCESSORIES intended to be introduced into the PATIENT;

- mammographic X-RAY EQUIPMENT;

- dental X-RAY EQUIPMENT.

NOTE 1 Examples of RADIOSCOPICALLY GUIDED INTERVENTIONAL PROCEDURES, for which the use of INTERVENTIONAL X-RAY EQUIPMENT complying with this document is recommended, are given in Annex AA.

NOTE 2 Specific requirements for magnetic navigation devices, and for the use of INTERVENTIONAL X-RAY EQUIPMENT in an operating room environment were not considered in this document; therefore, no specific requirements have been developed for these devices or uses. In any case, such devices or uses remain under the general clause requirements.

NOTE 3 INTERVENTIONAL X-RAY EQUIPMENT, when used for cone-beam CT mode, is covered by this document and not by IEC 60601-2-44 [1]1. No additional requirements for operation in cone-beam CT mode were identified for this document (see also Note 5 in 203.6.4.5).

INTERVENTIONAL X-RAY EQUIPMENT declared by the MANUFACTURER to be suitable for RADIOSCOPICALLY GUIDED INTERVENTIONAL PROCEDURES, which does not include a PATIENT SUPPORT as part of the system, is exempt from the PATIENT SUPPORT provisions of this document.

If a clause or subclause is specifically intended to be applicable to INTERVENTIONAL X-RAY EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to INTERVENTIONAL X-RAY EQUIPMENT and to ME SYSTEMS, as relevant.

IEC 60601-2-54 applies only with regards to the cited subclauses; non-cited subclauses of IEC 60601-2-54 do not apply.

1 Numbers in square brackets refer to the Bibliography.

Document History

EN IEC 60601-2-43
April 1, 2023
Medical electrical equipment Part 2: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures
This document applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of both FIXED and MOBILE X-RAY EQUIPMENT declared by the MANUFACTURER to be suitable for RADIOSCOPICALLY GUIDED INTERVENTIONAL...
September 1, 2020
Medical electrical equipment Part 2: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of both FIXED and MOBILE X-RAY EQUIPMENT declared by the MANUFACTURER to be suitable for RADIOSCOPICALLY GUIDED...
September 1, 2018
Medical electrical equipment Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures
Collateral standards Replace the existing second sentence of the second paragraph by the following: IEC 60601-1-8, IEC 60601-1-101), IEC 60601-1-112) and IEC 60601-1-123) do not apply.
October 1, 2014
Medical electrical equipment Part 2: Particular requirements for basic safety and essential performance of X-ray equipment for interventional procedures
A description is not available for this item.
August 1, 2011
Medical electrical equipment Part 2: Particular requirements for basic safety and essential performance of X-ray equipment for interventional procedures
La presente Norma Particolare stabilisce i requisiti per la sicurezza fondamentale e per le prestazioni essenziali, per la progettazione e la costruzione di apparecchiature a raggi X usate per le...
July 1, 2002
Medical electrical equipment - Part 2: Particular requirements for the safety of X-ray equipment for interventional procedures
E’ molto diffuso l’utilizzo di apparecchiature a raggi X per le procedure radiologiche interventistiche sotto controllo radioscopico. Questi esami possono utilizzare irradiazioni prolungate e possono...

References

Advertisement