NR/L2/SIG/11655
Management of Cable & Wire Insulation
| Organization: | NR |
| Publication Date: | 3 December 2011 |
| Status: | active |
| Page Count: | 10 |
scope:
This standard applies to signalling cable & wire insulation degradation on the infrastructure.
Inspection of wire insulation degradation on the signalling infrastructure is covered by NR/L3/SIG/31655.
Purpose
The safety integrity of the signalling system is at risk if cable/wire insulation is allowed to degrade. This standard specifies:
- The requirements for inspections
- The precautions to be taken during inspections
- Constraints to be placed on work where degradation is detected, and
- Action to be taken to remove degraded
wiring/installations
.
When the insulation degrades, the inner conductor can become exposed and come into contact with other exposed wires and terminals. The risks are that:
- Contacts are bypassed in a circuit
- Circuits are falsely energised
- Electrical shock, especially when carrying out hand tracing.
Document History