1.1 This specification covers the performance requirements and test methods designed to ensure the satisfactory performance of the portable hook-on chair. 1.2 This specification is intended to minimize injuries to children resulting from normal use and reasonably foreseeable misuse or abuse...
This specification deals with molybdenum wire and rod for electronic applications. The following grades of molybdenum wire and rod are covered in this specification: Grade 1-commercially pure molybdenum wire suitable for leads, hooks, supports, heaters, and metal-to-glass seals; Grade...
1.1 This specification covers titanium alloy bars with surface deformations and 90-degree anchorage hooks for use as near surface mounts for flexural and shear strengthening of concrete beams. The product can be furnished with or without anchorage hooks as specified by the purchaser....
This specification covers three types of drawn pure and thoriated tungsten wire suitable for fabrication into parts for electron tubes, lamps, and other electron devices, and one type of rod for metal-to-glass sealing (grid wire is excepted): Type 1A, Type 1B, Type 2A, and Type 2B. Types 1A and 1B...
5.1 This test method for the determination of cohesion in sliver, roving, or top in dynamic tests may be used for the acceptance testing of commercial shipments but caution is advised since information on between-laboratory precision is lacking. Comparative tests as directed in 5.1.1 may be...
1.1 This guide outlines how to visually assess exterior stone masonry walls and facades to determine their general condition. Examining key features of the construction can help identify and diagnose problems which require repairs or corrective action. Such an examination can expose conditions...
This specification covers high-strength, high conductivity round copper-alloy wire used for electronic hook-up wire. The wires shall conform to the required minimum breaking strength and elongation. Electrical resistance and diameter of the wire shall be measured. The finished material shall...
1.1 This standard covers the specification and qualification testing of insulating ladders used for performing live line work by electrical workers. 1.2 These insulating ladders are used to provide access, generally on overhead power line structures and to facilitate live line work with live line...
This specification provides design and construction criteria for double and single fire and foam station cabinets. These cabinets are classified as Type I (single cabinet) and Type II (double cabinets). Type I cabinets are further subdivided into two grades: Grade 1 which has a right-hand door and...
5.1 Firefighters are routinely exposed to radiant heat in the course of their fireground activities. In some cases, firefighters have reported burn injuries under clothing where there is no evidence of damage to the exterior or interior layers of the firefighter protective clothing.5 Low levels of...
This test method covers the determination of the efficiency of ordinary commercial wetting agents using the skein test. It is applicable under limited and controlled conditions, but does not necessarily yield information correlating with specific end uses. The apparatus is comprised of a...
This SAE Aerospace Recommended Practice (ARP) covers the recommended criteria and performance requirements for the design and installation of land-based aircraft emergency and operational arresting hooks for use on runway arresting systems. Design criteria for fully operational hooks...
This specification establishes the recognized performance requirements and corresponding test procedures for portable and permanent emergency escape ladders for residential use. The ladder shall show evidence of good workmanship and meet the requirements specified for the following: vertical static...
1.1 This standard identifies terminology related to subassemblies which are categorized as any component that is used in the construction or assembly of a textile product. Subassemblies can be in the form of components used as closures (for example, slide fasteners, buttons, snap fasteners,...
This specification covers design criteria requirements, design geometry, material characteristics, and desirable features for oil spill response boom connections. These criteria are intended to define minimum mating characteristics and are not intended to be restrictive to a specific configuration....
1.1 This test method measures the shear strength of hook and loop touch (CRE) fasteners using a recording constant rate of extension tensile testing machine. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions...
1.1 This test method covers the measurement of the peel strength of hook and loop touch fasteners using a recording constant-rate-of-ext
1.1 This specification covers swaged welded, cast, or forged turnbuckles with and without jam nuts. 1.2 A turnbuckle is an internally threaded loop or sleeve intended for assembly with a threaded stud, eye, hook, or jaw at each end, used for applying tension to rods, wire rope, and so forth....
Purpose. This procedure determines the resistance of interior materials to hook fastener abrasion. Hook fasteners on customers' clothing or consumer goods such as luggage, if left open, have small hooks or barbs that may damage the surface of interior materials through contact...
This specification describes the manufacturing requirements for spray shield stock and the fabrication and installation requirements for spray shields made from that stock. The physical and mechanical properties for the aluminized glass cloth, thread, and protective outer jacket shall be as...
Narrow Your Results