loading
IEC 62282-6-400 - Fuel cell technologies – Part 6-400: Micro fuel cell power systems – Power and data interchangeability
May 1, 2019 - IEC

This part of IEC 62282 covers the interchangeability of power and data between micro fuel cell power systems and electronic devices to provide the micro fuel cell power system compatibility for a variety of electronic devices while maintaining the safety...

IEC 61076-2-012 - Connectors for electrical and electronic equipment – Product requirements – Part 2‑012: Circular connectors – Detail specification for connectors with inner push‑pull locking based on M12 connector interfaces according to IEC 61076‑2‑101, IEC 61076‑2‑109, IEC 61076‑2‑111 and IEC 61076‑2‑113
July 1, 2020 - IEC

This part of IEC 61076 specifies circular connectors with an inner push‑pull locking mechanism of a size derived from and thus being compatible with M12 screw‑locking connectors and with mating interfaces according to IEC 61076‑2‑101, IEC 61076‑2‑109, IEC...

IEC 62282-6-300 - Fuel cell technologies – Part 6-300: Micro fuel cell power systems – Fuel cartridge interchangeability
December 1, 2012 - IEC

This part of IEC 62282 covers interchangeability of micro fuel cell (MFC) fuel cartridges to provide the cartridge compatibility for a variety of MFC power units while maintaining the safety and performance of MFC power systems. For this purpose, the standard covers fuel...

EIA-967 - Specification for Micro Serial Attachment 3 Gbs 4X Unshielded Connector
November 1, 2012 - ECIA

This specification defines the terminology and physical requirements for the mating interface and physical characteristics of the Micro SAS Connector System. It is designed to support high speed serial signals and power. While designed specifically for the smaller, 1.8 inch...

IEC 61169-49 - Radio-frequency connectors – Part 49: Sectional specification for SMAA series R.F connectors
May 1, 2014 - IEC

This part of IEC 61169, which is a sectional specification (SS) , provides information and rules for the preparation of detail specifications (DS) for type SMAA series thread mated coaxial connectors. The connectors are normally used for micro wave applications,...

IEC 61076-3-118 - Connectors for electronic equipment – Product requirements – Part 3-118: Rectangular connectors – Detail specification for a 4 pole plus PE power connector with push-pull coupling
April 1, 2010 - IEC

General considerations This part of IEC 61076 establishes specifications and test requirements for a connector with four contacts plus PE contact, for use in industrial environments. NOTE For a definition of PE, see IEV, for example IEV 195-02-09. This International Standard specifies...

IEC 61076-3-120 - Connectors for electronic equipment - Product requirements – Part 3-120: Rectangular connectors – Detail specification for rewirable power connectors with snap locking for rated voltage of 250 V d.c. and rated current of 30 A
August 1, 2016 - IEC

This part of IEC 61076-3 describes a 2 pole 30 A rectangular power connector with snap locking (hereinafter shortly referred to as connector), including overall dimensions, interface dimensions, technical characteristics, performance requirements and test methods. The...

IEC PAS 61076-2-010 - Connectors for electrical and electronic equipment – Product requirements – Part 2-010: Circular connectors – Detail specification for push-pull connectors with locking mechanism, based on mating interfaces according to IEC 61076-2-101, IEC 61076-2-109, IEC 61076-2-111 and IEC 61076-2-113
July 1, 2020 - IEC

This part of IEC 61076 specifies circular connectors with a push-pull locking mechanism of a size derived from and thus being compatible with M12 screw-locking connectors (free connectors with screw-locking according to IEC 61076-2-101, IEC 61076-2-109,...

IEC PAS 61076-3-126 - Connectors for electrical and electronic equipment – Product requirements – Part 3-126: Rectangular connectors – Detail specification for 5 pole power connectors for industrial environments with push-pull locking
January 1, 2018 - IEC

This document covers rectangular IP65/IP67 connectors with 5 poles for electric power supply up to 16 A. These connectors consist of fixed and free connectors, either rewirable or nonrewirable (for both portions). It uses the general function principles of the push-pull...

IEC 61169-45 - Radio-frequency connectors – Part 45: Sectional specification for SQMA series quick lock RF coaxial connectors
May 1, 2014 - IEC

This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for type SQMA quick lock RF coaxial connectors. The connectors are normally used with 50 Ω in microwave, telecommunication, wireless...

IEC 60603-7-82 - Connectors for electronic equipment - Part 7-82: Detail specification for 8-way, 12 contacts, shielded, free and fixed connectors, for data transmission with frequencies up to 2 000 MHz
August 1, 2016 - IEC

This part of IEC 60603 covers 8-way, 12 contacts, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7-7, and specifies electrical transmission requirements, including power sum...

IEC 61169-26 - Radio-frequency connectors – Part 26: Sectional specification for TNCA series RF coaxial connectors
January 1, 2013 - IEC

This part of IEC 61169 which is a sectional specification (SS) provides information and rules for the preparation of detail specifications (DS) for TNCA series RF coaxial connectors, with characteristic impedance of 50 Ω, with threaded coupling and operating frequency limit up to 18...

IEC 61076-2-111 - Connectors for electrical and electronic equipment – Product requirements – Part 2-111: Circular connectors – Detail specification for power connectors with M12 screw-locking
December 1, 2017 - IEC

This part of IEC 61076-2 specifies 4 to 6-way circular connectors with M12 screw-locking with current ratings up to 16 A and voltage ratings of 63 V or 630 V, that are typically used for power supply and power applications in industrial premises. These connectors...

J1962_201607 - Diagnostic Connector
July 12, 2016 - SAE International

This document supersedes SAE J1962 200204, and is technically equivalent to ISO/DIS 15031-3: December 14, 2001. This document is intended to satisfy the requirements of an OBD connector as required by U.S. On-Board Diagnostic (OBD) regulations. The diagnostic connection specified in this...

IEC 60603-7-71 - Connectors for electronic equipment – Part 7-71: Detail specification for 8-way, shielded, free and fixed connectors, for data transmission with frequencies up to 1 000 MHz
June 1, 2010 - IEC

This part of IEC 60603 covers 8-way, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603- 7, and specifies electrical transmission requirements, including power sum alien (exogenous)...

IEC 61238-1 - Compression and mechanical connectors for power cables for rated voltages up to 30 kV (Um = 36 kV) Part 1: Test methods and requirements
May 1, 2003 - IEC

Scope and object This part of IEC 61238 applies to compression and mechanical connectors for power cables for rated voltages up to 30 kV (Um = 36 kV), e.g. buried cables or cables installed in buildings, having a) conductors complying with IEC 60228 and IEC 60228A...

IEC/IEEE 60076-16 - Power transformers – Part 16: Transformers for wind turbine applications
September 1, 2018 - IEC

This part of IEC 60076 applies to dry-type and liquid-immersed transformers for wind turbine step-up applications having a winding with highest voltage for equipment up to and including 72,5 kV. This document applies to the transformer used to connect the wind turbine generator to the...

IEC 60076-16 REDLINE - Power transformers – Part 16: Transformers for wind turbine applications
September 1, 2018 - IEC

This part of IEC 60076 applies to dry-type and liquid-immersed transformers for wind turbine step-up applications having a winding with highest voltage for equipment up to and including 72,5 kV This document applies to the transformer used to connect the wind turbine generator to the...

IEC 60603-7-51 - Connectors for electronic equipment – Part 7-51: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 500 MHz
March 1, 2010 - IEC

This part of IEC 60603 covers 8-way, shielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7, and specifies electrical transmission requirements, including power sum alien (exogenous)...

IEC 60603-7-41 - Connectors for electronic equipment – Part 7-41: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 500 MHz
March 1, 2010 - IEC

This part of IEC 60603 covers 8-way, unshielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7, and specifies electrical transmission requirements, including power sum alien...

Advertisement