This specification covers a corrosion-resistant steel in the form of sand or centrifugal castings.
This specification covers magnesium-alloy sand castings. The castings shall conform to the chemical composition limits specified. The castings may be subjected to such heat treatment as deemed necessary to produce material that will conform to the requirements specified. Heat treatment shall...
1.1 This specification covers brick made principally from sand and lime and intended for use in brick masonry. Two grades of brick are covered: 1.1.1 Grade SW-Brick intended for use where exposed to temperature below freezing in the presence of moisture. Note 1: As a typical example, brick...
1.1 This guide covers the physical and chemical requirements of virgin or recovered foundry sand for use as a fine aggregate in asphalt mixtures. 1.2 This guide is for use by contractors, foundry sand suppliers, or other purchasers as part of the purchase document describing the...
5.1 The Device record includes information about how the heat butt fusion joint was made (heater temperature, pressures and times for the heating, fusion and cooling steps) and other important information about the process, job, equipment used, etc. The Device record is compared to the specified...
This specification defines the requirements for grading and quality of fine and coarse aggregate for use in concrete. Fine aggregate shall consist of natural sand, manufactured sand, or a combination thereof. Fine aggregate shall be free of injurious amounts of organic impurities....
This specification covers the construction of marine berths for officers, crew, and passengers. Berths shall be classified according to types: Type I; Type IA; Type II; Type IIA; Type III; and Type IIIA. Metal components shall be joined by welding. Spotweld depressions, on exposed surfaces, shall...
This practice covers the application of mineral-colloid-stab
5.1 During preconstruction and construction evaluations, use of these test methods establishes specific and overall performance characteristics for the mortar system. 5.2 Preconstruction testing of mortars prebatched by weight provides information for the selection of the individual mortar system...
1.1 This specification covers brick made principally from sand and lime and intended for use in brick masonry. Two grades of brick are covered: 1.1.1 Grade SW-Brick intended for use where exposed to temperature below freezing in the presence of moisture. Note 1: As a typical example, brick...
This test method covers the determination of nonvolatile content or total solids of liquid phenol, resorcinol, and melamine adhesives with or without hardener added and containing high-boiling and low-boiling volatile organic solvents or water, or both. The equipments to be used in the test shall...
This specification covers design criteria requirements, design geometry, material characteristics, and desirable features for oil spill response boom connections. These criteria are intended to define minimum mating characteristics and are not intended to be restrictive to a specific configuration....
5.1 Silicon (Si), a metalloid, is the second most abundant element in the earth's crust. Various forms of silica (silicon dioxide SiO2) are found in quartz, sand, and rocks. The degradation of these rocks results in silica found in natural waters. Silica in natural waters can be found as...
This specification covers requirements for copper alloy sand castings for general applications. The components part casting may be manufactured in advance and supplied from stock. The castings shall conform to the compositional requirements for named elements specified. Mechanical properties...
1.1 This test method covers the determination of the sand content of bentonitic slurries used in slurry construction techniques. This test method has been modified from API Recommended Practice?13B. 1.2 All observed and calculated values shall conform to the guidelines for significant digits...
This specification covers thin veneer brick units made from clay, shale, fire clay, sand, or mixtures thereof, and fired to incipient fusion for use in adhered or fastened veneer applications. The brick units shall be available in both Grades Interior and Exterior of the following types:...
This specification covers the standard requirements for the application of full thickness Portland cement-based plaster for exterior (stucco) and interior work. It also sets forth tables for proportioning of various plaster mixes and plaster thickness. The materials used shall consist of the...
This specification covers three types of masonry cement for use where mortar for masonry is required. Masonry cement shall conform to the applicable physical property requirements prescribed. The masonry cement shall be sampled in accordance with practice C 183. The temperature and relative...
5.1 This test method assigns an empirical value to the relative amount, fineness, and character of clay-like material present in the test specimen. 5.2 A minimum sand equivalent value may be specified to limit the permissible quantity of clay-like or clay-size fines in an aggregate. 5.3 This...