loading
IEEE C57.12.37 - The Electronic Reporting of Distribution Transformer Test Data
September 3, 2015 - IEEE

This standard provides a basis for electronic reporting of transformer test data on liquid-immersed distribution transformers. This standard defines how to format and report the standard test data when electronic reporting is specified. In addition, it defines an...

IEEE 1388 - Standard for the Electronic Reporting of Transformer Test Data
December 7, 2000 - IEEE

This standard provides a basis for electronic reporting of transformer test data on liquid immersed distribution transformers, specifically, those defined in the ANSI C57.12.2X standards series. This standard defines the standard set of test data to be reported and the...

IEEE C57.98 - Guide for Transformer Impulse Tests
December 11, 2011 - IEEE

To aid in the interpretation and application of the impulse testing requirements of the IEEE Standard Test Codes for Transformers. Purpose This guide is written primarily for power transformers, but it is also generally applicable to distribution and instrument...

NG SCT 20.01 - Site Commissioning Tests - Current Transformers Mangnetisation Tests
April 1, 2014 - NG

PURPOSE AND SCOPE This document contains the site commissioning tests to be performed on Current Transformers in National Grid (NG) substations.'

IEEE 93 - GUIDE FOR TRANSFORMER IMPULSE TESTS
June 21, 1968 - IEEE
A description is not available for this item.
DIN 44766-4 - Resistance welding transformers; requirements, tests
May 1, 1981 - DIN
A description is not available for this item.
MPIF STANDARD TEST - Standard Test Methods for Metal Powders and Powder Metallurgy Products
January 1, 2019 - MPIF

Introduction & Scope The Metal Powder Industries Federation (MPIF) is a voluntary-membership, not-for-profit trade association formed by the members of the PM and particulate materials industry to promote the advancement of the metal powder producing and consuming industries and the practice of...

DSF/PREN 50708-2-4 - Power transformers – Additional European requirements – Part 2-4: Medium power transformer – Special tests
DS

This document describes the special test for Medium Power Transformers ≤ 3150kVA compliant with the EN 50708 2 series: - for corrugated tank liquid immersed transformers; - for the method of measurement of losses for one winding in Highest Voltage (HV) and 2 windings in Lowest...

NG SCT 20.02 - Site Commissioning Tests - Current Transformers Primary Injection Tests
January 1, 2000 - NG
A description is not available for this item.
IEEE 389 - Recommended Practice for Testing Transformers and Inductors for Electronics Applications
March 5, 2020 - IEEE

This recommended practice presents a number of tests for use in determining the significant parameters and performance characteristics of electronics transformers and inductors. These tests are designed primarily for transformers and inductors used in all types of...

JIS C 1731 - Instrument Transformers for Testing Purpose and Used with General Instrument
March 1, 1988 - JSA
A description is not available for this item.
DSF/PREN 50708-3-4 - Power transformers – Additional European requirements – Part 3-4: Large power transformer – Special tests for corrugated tank and radiators
DS

This document describes a special test for hermetically sealed transformers with integral filling equipped with corrugated tank or tank with expandable radiators for Large Power Transformers > 3 150 kVA.

ANSI C12.9 - Test Switches and Plugs for Transformer-Rated Meters
January 1, 2014 - NEMA

This standard is intended to encompass the dimensions and functions of meter test switches used with transformer-rated watthour meters in conjunction with instrument transformers and test plugs used in conjunction with the test switch.

IEEE C57.13.2 - Standard Conformance Test Procedures for Instrument Transformers
June 9, 2005 - IEEE

This standard describes the tests and documentary requirements for conducting a conformance test on instrument transformers.

IEEE C57.138 - Recommended Practice for Routine Impulse Tests for Distribution Transformers
December 7, 2016 - IEEE

This recommended practice covers routine impulse tests performed on distribution transformers, as required in IEEE Std C57.12.00™, and described in 10.4 of IEEE Std C57.12.90™-20151. Distribution transformers covered by this recommended practice are liquid-immersed, single- and...

NG SCT 30 - Site Commissioning Tests - Transformer Automatic Voltage Control Equipment
August 1, 1998 - NG
A description is not available for this item.
DS/EN 60076-4 - Power transformers - Part 4: Guide to lightning impulse and switching impulse testing - Power transformers and reactors
October 24, 2002 - DS

This part of IEC 60076 gives guidance and explanatory comments on the existing procedures for lightning and switching impulse testing of power transformers to supplement the requirements of IEC 60076-3. It is also generally applicable to the testing of reactors, see IEC 60289;...

Advertisement