1.1 These requirements cover hose and hose assemblies in sizes up to and including a nominal internal diameter of 4 in (102 mm) for conveying liquefied petroleum gas (LP-Gas) intended to be installed in closed systems in compliance with the Standard of the National...
1.1 These requirements cover rack or reel type semiautomatic fire hose storage devices (SHSD) optionally installed in a cabinet intended for use in controlling incipient fires by trained personnel. An SHSD is intended for use with specifically-identif
1.1 These requirements cover flexible metallic hose supplied with fittings on each end that facilitate connection without twisting the hose. They have a corrugated metal core or a nonmetallic inner core which are covered with a stainless steel braid. They have a nominal inside...
1.1 These requirements cover angle-pattern and straightway-pattern hose valves intended for use on standpipes, fire pumps, and hydrants supplying water for fire protection service. 1.2 Requirements for the installation of hose valves include the Standards of the National...
1.1 These requirements cover lined interior standpipe fire hose in the 1-1/2 and 2-1/2 inch sizes that is intended: a) For fire-protection purposes only; b) For use with inside standpipes installed in accordance with the Standard for the Installation of Standpipe and...
1.1 These requirements cover single- and multiple-jacketed lined fire hose with or without couplings attached, in the trade sizes of 1-1/2, 1-3/4, 2, 2-1/4, 2-1/2, 2-3/4, 3, 3-1/2, 4, 4-1/2, 5, and 6 inch (38, 45, 51, 57, 65, 70, 76, 89, 102, 114, 127, and 152 mm nominal ID)....
This standard shall define the design and construction requirements for new fire hose, the testing required to verify the design and construction, and the inspection and testing required of all new fire hose.
1.1 These requirements cover pigtails and flexible hose connectors used in the assembly of fuel-supply systems other than those outlined in 3 (b) and (c), intended for liquefied petroleum gas (LP-Gas). Low or high pressure flexible hose connectors are also suitable for...
1.1 These requirements cover portable hand line spray hose nozzles intended for general fire fighting or for use with fire hose mounted on standpipe systems. 1.2 Requirements for the installation and use of spray nozzles used in standpipe systems are intended to be in...
This standard shall cover the requirements for fire hose appliances up to and including 6 in. (150 mm) nominal dimension designed for connection to fire hose, fire apparatus, and fire hydrants and intended for general fire service use in controlling...
This standard gives the performance and requirements for new fire hose couplings and adapters with nominal sizes from ¾ in. (19 mm) through 8 in. (200 mm) and the specifications for the screw thread connections on those couplings and adapters. This standard also gives the performance...
This standard prescribes standardized fire and hose stream test procedures that apply to fire door assemblies intended to be used to retard the spread of fire through door openings in fire-resistive walls. Purpose. The purpose of this standard is to prescribe...
The test described in this procedure shall be used to determine the fire resistance of passive fire protection (PFP) materials applied to the exterior of LP-Gas containers. Purpose. This test is designed to evaluate the fire resistance of passive fire protection...
This standard includes minimum requirements for dry chemical fire-extinguishing systems that discharge dry chemical from fixed nozzles or hand hose lines by means of expellant gas.
The provisions of this standard apply to the selection, installation, inspection, maintenance, and testing of portable extinguishing equipment. Portable fire extinguishers are intended as a first line of defense to cope with fires of limited size. The selection and installation of...
This specification covers straight and curved coolant hose intended for use as long life radiator hose, heater hose and other flexible conduits for automotive engine cooling systems. Such products are intended to withstand the effects of circulating solutions containing...
This specification covers straight and curved coolant hose intended for use as long life radiator hose, heater hose and other flexible conduits for automotive engine cooling systems, Such products are intended to withstand the effects of circulating solutions containing...
1.1 This Standard covers flexible sprinkler hose with fittings intended for direct connection to fire sprinklers in installations requiring a flexible attachment to the sprinkler system piping such as clean rooms, suspended ceilings, and exhaust ducts. 1.2 The products covered by this...
1.1 This Standard covers flexible sprinkler hose with fittings intended for direct connection to fire sprinklers in installations requiring a flexible attachment to the sprinkler system piping such as clean rooms, suspended ceilings, and exhaust ducts. 1.2 The products covered by this...